Commercial
Advanced Search

Vagus Nerve Stimulation (VNS)
11.15.16y

Policy

MEDICALLY NECESSARY

Implantable vagus nerve stimulation (VNS) is considered medically necessary and, therefore, covered for the treatment of individuals who have medically refractory seizures and for whom surgery is not recommended or has failed.

EXPERIMENTAL/INVESTIGATIONAL

IMPLANTABLE VAGUS NERVE STIMULATION
Implantable VNS is considered experimental/investigational for all other conditions including but not limited to the following conditions and, therefore, not covered because the safety and/or effectiveness of this service cannot be established by review of the available published peer-reviewed literature:
  • Depression, refractory
  • Essential tremor​
  • Fibromyalgia
  • Headache/migraine
  • Heart failure, chronic
  • Obesity​
  • ​Obsessive-compulsive disorder (OCD)
  • Tinnitus
  • Traumatic brain injury
  • Upper-limb impairment due to stroke
NON-IMPLANTABLE VAGUS NERVE STIMULATION
Non-implantable VNS is considered experimental/investigational and, therefore, not covered because the safety and/or effectiveness of this service cannot be established by review of the available published peer-reviewed literature in the treatment for conditions including, but not limited to, the following:
  • Cluster headaches
  • Epilepsy
  • Fibromyalgia
  • Impaired glucose tolerance
  • Migraine headaches
  • ​Psychiatric disorders including, but not limited to, depression and schizophrenia
  • Upper-limb impairment due to stroke
REQUIRED DOCUMENTATION

The individual's medical record must reflect the medical necessity for the care provided. These medical records may include, but are not limited to: records from the professional provider's office, hospital, nursing home, home health agencies, therapies, and test reports.

The Company may conduct reviews and audits of services to our members, regardless of the participation status of the provider. All documentation is to be available to the Company upon request. Failure to produce the requested information may result in a denial for the service.

US FOOD AND DRUG ADMINISTRATION (FDA) STATUS 
Although the FDA has approved a de​vice  (i.e., vagus nerve blocking therapy)​ ​for implantable VNS for use in the treatment of individuals who have obesity, the Company has determined that the safety and/or effectiveness of this service cannot be established by review of the available published peer-reviewed literature.​ Therefore, implantable VNS for use in the treatment of individuals who have obesity is considered experimental/investigational by the Company and not covered. 

Although the FDA has approved a device (i.e., MicroTransponder ViviStim Paired Vagus Nerve Stimulation system) for implantable VNS for use in the treatment of individuals who have upper-limb impairment due to stroke, the Company has determined that the safety and/or effectiveness of this service cannot be established by review of the available published peer-reviewed literature. Therefore, implantable VNS for use in the treatment of individuals who have upper-limb impairment due to stroke is considered experimental/investigational by the Company and not covered. 

Although the FDA has approved a device (i.e., gammaCore™ non-invasive vagus nerve stimulator [nVNS]), for non-implantable VNS for use in the treatment of pain associated with cluster headaches in adults (including episodic cluster headaches in adults, and as a therapy for adjunctive use for the preventive treatment of cluster headache in adults) and in the treatment of pain associated with migraine headaches, the Company has determined that the safety and/or effectiveness of this service cannot be established by review of the available published peer-reviewed literature. Therefore, nonimplantable VNS for treatment of cluster headaches in adults and in the treatment of pain associated with migraine headaches ​is considered experimental/investigational by the Company and not covered. ​

Guidelines

BENEFIT APPLICATION

Subject to the terms and conditions of the applicable benefit contract, vagus nerve stimulation (VNS) is covered under the medical benefits of the Company’s products when the medical necessity criteria listed in this medical policy are met.

US FOOD AND DRUG ADMINISTRATION (FDA) STATUS

​NEUROCYBERNETIC PROSTHESIS (NCP®)/VNS THERAPY® SYSTEM/SYMMETRY®​ VNS THERAPY SYSTEM
On July 16, 1997, the FDA approved the use of the VNS Therapy® System (LivaNova USA, Inc., formerly Cyberonics, Inc., Houston, TX), a VNS device, for the adjunctive treatment of medically refractory partial-onset seizures in adults and children 12 years of age or older.

On July 15, 2005, the FDA approved the use of the VNS Therapy® System for the adjunctive long-term treatment of chronic or recurrent depression in individuals 18 years of age or older who have experienced a major depressive episode and have not adequately responded to four or more antidepressant treatments.

On June 23, 2017, the FDA approved the use of the VNS Therapy® System as an adjunctive therapy for seizures in individuals 4 years of age or older with partial-onset seizures that are refractory to antiepileptic medications.

MAESTRO® RECHARGEABLE SYSTEM
On January 14, 2015, the FDA approved the MAESTRO® Rechargeable System (EnteroMedics, Inc., St. Paul, MN), for use in weight reduction in individuals aged 18 years through adulthood who have a body mass index (BMI) of 40 to 45 kg/m2, or a BMI of 35 to 39.9 kg/m2 with one or more obesity-related comorbid conditions, and have failed at least one supervised weight management program within the past 5 years.

The commercial availability of the Maestro® Rechargeable System is unclear. On the FDA's Weight-Loss and Weight-Management Devices webpage, the Maestro® Rechargeable System is described as "no longer marketed as of September 2018." Additionally, on the ReShape Lifesciences website (previously EnteroMedics), the Maestro® Rechargeable System is not listed among their current portfolio of medical devices to treat obesity and metabolic disease. However, updates to the Maestro® Rechargeable System were noted in the FDA Premarket Approval database (P130019) subsequent to September 2018, including updates to the circuit assembly and application firmware of the mobile charger and approval of modifications to the follow-up schedule for the post​approval study protocol.

GAMMACORE® NON-INVASIVE VAGUS NERVE STIMULATOR (GAMMACORE-S®/GAMMACORE-2®/GAMMACORE-SAPPHIRE®)
On May 30, 2017, the FDA approved the gammaCore-S® Non-Invasive Vagus Nerve Stimulator (ElectroCore, LLC, Basking Ridge, NJ) for the use in the acute treatment of pain associated with episodic cluster headache in adult patients.

On January 23, 2018, the FDA expanded their approval of the gammaCore-S® Non-Invasive Vagus Nerve Stimulator to include the use in the acute treatment of pain associated with migraine headache in adult patients.

On November 27, 2018, the FDA expanded their approval of the gammaCore-Sapphire® Non-Invasive Vagus Nerve Stimulator to include the adjunctive use for the preventive treatment of cluster headache in adult patients.

On March 26, 2020, the FDA expanded their approval of the gammaCore-Sapphire® Non-Invasive Vagus Nerve Stimulator to include the use in the preventive treatment of migraine headache in adult patients.

On February 12, 2021, the FDA expanded their approval of the gammaCore-Sapphire® Non-Invasive Vagus Nerve Stimulator to include:
  • The preventive treatment of migraine headache in adolescents (age 12 and older), and
  • The acute treatment of pain associated with migraine headache in adolescents (age 12 and older).
On September 10, 2021, the FDA expanded their approval of the gammaCore-Sapphire® Non-Invasive Vagus Nerve Stimulator to include:
  • Treatment of hemicrania continua in adults, and
  • Treatment of paroxysmal hemicrania in adults
MICROTRANSPONDER® VIVISTIM® PAIRED VNS SYSTEM (VIVISTIM® SYSTEM)
On August 27, 2021, the FDA approved the Vivistim® Paired VNS™ System (MicroTransponder, Inc., Austin, TX), to be used to stimulate the vagus nerve during rehabilitation therapy in order to reduce upper extremity motor deficits and improve motor function in chronic ischemic stroke patients with moderate to severe arm impairment.

Description

IMPLANTABLE VAGUS NERVE STIMULATION

MEDICALLY AND SURGICALLY REFRACTORY SEIZURES
Vagus nerve stimulation (VNS) has been evaluated as an alternative treatment for individuals with medically refractory seizures for whom surgery is not recommended or has failed. Seizures that are not completely controlled by medical therapy, or seizures that cannot be treated with therapeutic levels of antiepileptic drugs because of intolerable adverse effects of these drugs, are referred to as medically refractory seizures.

Seizures are considered paroxysmal disorders (i.e., characterized by abnormal cerebral neuronal discharge) and occur when there is errant electrical discharge activity in the brain. Seizures cause different physical symptoms depending on the location of the electrical activity in the brain. They may be mild to severe, ranging from causing a slight tingling sensation or momentary confusion to causing complete unconsciousness. Classification and subtypes of seizures are commonly diagnosed by electroencephalography (EEG). Seizures are classified as simple partial, complex partial, and generalized onset, and are distinguished on the basis of the level of consciousness.

Partial seizures affect only a portion, or one hemisphere, of the brain and are subdivided into the following:
  • ​Simple partial seizures
    • ​Awareness is unimpaired; there is no alteration of consciousness.
  • ​Complex partial seizures
    • ​​Awareness is impaired; an alteration of consciousness is usually involved.
  • ​Simple or complex partial seizures that may become secondarily generalized, leading to tonic, clonic, or tonic-clonic seizures
    • There is complete loss of consciousness.
Generalized seizures are caused by errant electrical activity in multiple locations, or large areas, that may involve both the left and the right hemispheres of the brain. This type of seizure has a more complex set of symptoms, with impaired awareness leading to complete loss of consciousness. The subtypes of generalized seizures are usually classed as follows:
  • ​Absence seizures (formerly petit mal)
    • ​Awareness is briefly impaired, sometimes accompanied by mild clonic, tonic, or atonic components. Onset and endings are abrupt.
  • ​Atypical absence seizures
    • ​More marked symptoms, and more gradual onset and ending than occur in typical absence seizures.
  • ​Myoclonic seizures
    • ​Awareness is usually not impaired, with single or multiple sudden contractions of muscle groups.
  • ​Tonic-clonic seizures (formerly grand mal)
    • Usually complete loss of consciousness accompanied by sudden, brief muscle contractions.
Epilepsy is diagnosed in individuals who have a predisposition for recurrent, unprovoked seizures. During the past 10 years, new medications and surgical techniques have emerged in the treatment of epilepsy. Despite these advances, 20% to 50% of individuals with epilepsy have breakthrough seizures or experience adverse effects of antiseizure medications. Current peer-reviewed medical literature supports VNS as a useful palliative procedure for individuals who have severe generalized epilepsy with atonic or tonic-clonic seizures. Peer-reviewed literature also supports the use of VNS as an effective treatment for medically refractory seizures other than partial-onset seizures.

The VNS system is composed of an implantable generator, a bipolar electrical lead (array) consisting of helical electrodes and an anchor tether, along with an external programming device that is used to change stimulation settings. Revisions to the VNS system may include procedures such as replacing the battery-powered generator. Battery longevity depends on stimulation parameters, with newer battery-powered generators lasting up to 10 years or more. The generator is surgically implanted subcutaneously, at the lateral border of the left pectoral muscle, or under the arm. An incision is also made to the left side of the neck, to access the vagus nerve, for the placement of the electrodes. The lead (array) is threaded subcutaneously to connect the electrodes, which are attached to the vagus nerve, to the generator. Once implantation is completed, the generator is programmed to stimulate the vagus nerve at regular intervals.

The basic principles of VNS when used as a treatment for epilepsy are that vagal visceral afferents (nerves that convey impulses from sense organs and other receptors to the brain or spinal cord) have a diffuse central nervous system projection, and the activation of these pathways has a widespread effect upon neuronal excitability. The exact mechanism of VNS on neuronal excitability is not fully known. Adverse effects of VNS therapy include headache, neck pain, cough, and voice alterations.

Some of the benefits of using VNS may include less-severe or shorter seizures, a reduction in seizure frequency, improved recovery periods after seizures, and a lessening of seizure clusters. Individuals undergoing VNS must be aware that seizure control improves over time, and that although VNS may reduce the frequency and magnitude of seizure activity, the need remains for an ongoing, concurrent, anti-seizure medicinal regimen.

On July 16, 1997, the US Food and Drug Administration (FDA) approved the NeuroCybernetic Prosthesis (NCP®) System/VNS Therapy® System (LivaNova USA, Inc., formerly Cyberonics, Inc., Houston, TX), a VNS device, for the adjunctive treatment of medically refractory partial-onset seizures in adults and children 12 years of age or older. Studies since the original FDA approval have focused on the use of VNS in younger children. On June 23, 2017, the FDA approved the use of the VNS Therapy® System as an adjunctive therapy for seizures in individuals 4 years of age or older with partial-onset seizures that are refractory to antiepileptic medications.

Systematic Reviews 

In 2011, Englot et al. performed a meta-analysis of VNS efficacy in epilepsy, identifying 74 clinical studies with 3321 individual suffering from intractable epilepsy. These studies included three blinded, randomized controlled trials (RCTs) (Class I evidence); two nonblinded RCTs (Class II evidence); 10 prospective studies (Class III evidence); and numerous retrospective studies. After VNS, seizure frequency was reduced by an average of 45%, with a 36% reduction in seizures between 3 and12 months after surgery and a 51% reduction after more than 1 year of therapy. At the last follow-up, seizures were reduced by 50% or more in approximately 50% of the individuals, and VNS predicted a 50% or more reduction in seizures with a main effects odds ratio [OR] of 1.83 (95% confidence interval [CI], 1.80–1.86). Individuals with generalized epilepsy and children benefited significantly from VNS despite their exclusion from initial approval of the device. Furthermore, posttraumatic epilepsy and tuberous sclerosis were positive predictors of a favorable outcome. The authors concluded that "VNS is an effective and relatively safe adjunctive therapy in patients with medically refractory epilepsy not amenable to resection. However, it is important to recognize that complete seizure freedom is rarely achieved using VNS and that a quarter of patients do not receive any benefit from therapy."

In 2012, Connor et al. conducted a study to evaluate the published results of VNS for medically refractory seizures according to evidence-based criteria. Inclusion criteria for articles included more than 10 individuals evaluated, average follow-up of 1 or more years, inclusion of medically refractory epilepsy, and consistent preoperative surgical evaluation. Twenty publications were included. Most studies supported use of VNS for partial epilepsy. A majority of individuals achieved seizure reduction of 50% or more, freedom from seizures in 6% to 27% of individuals who responded to treatment. The authors concluded that "vagal nerve stimulation is a safe and effective alternative for adult and pediatric populations with epilepsy refractory to medical and other surgical management."

In 2014, Fisher et al. published a systematic review evaluating what is known about the use, effectiveness, and safety of magnet mode stimulation of VNS Therapy. The review included 20 clinical studies of individuals with medically refractory epilepsy (n=829). Benefit was reported in a weighted average of 45% of individuals (range, 0%–89%) using the magnet, with seizure cessation claimed in a weighted average of 28% (range, 15%–67%). In addition to seizure termination, individuals sometimes reported decreased intensity or duration of seizures or the postictal period. One study reported an isolated instance of worsening with magnet stimulation. All of the reviewed studies assessed adjunctive magnet use. No studies were designed to provide Level I evidence of efficacy of magnet-induced stimulation. Retrospective analysis of one pivotal randomized trial of VNS therapy showed significantly more seizures terminated or improved in the active stimulation group vs the control group. Prospective, controlled studies would be required to isolate the effect and benefit of magnet mode stimulation and to document that the magnet-induced stimulation is the proximate cause of seizure reduction. Manual application of the magnet to initiate stimulation is not always practical because many individuals are immobilized or unaware of their seizures, asleep or not in reach of the magnet. 

In 2015, Panebianco et al. updated a Cochrane systematic review and meta-analysis of VNS to treat partial seizures. The authors specifically evaluated randomized, double-blind, parallel or crossover, controlled trials (RCTs) of VNS as add-on treatment comparing high- and low-stimulation paradigms plus VNS stimulation with no stimulation or different intervention. Five trials (n=439) compared high-frequency stimulation with low-frequency stimulation in individuals ages 12 to 60 years, and another trial compared high-frequency stimulation with low-frequency stimulation in children. Risk of bias was rated as low for most domains across studies. However, none of the protocols for the included studies were available and therefore were rated as having an unclear risk of bias for selective reporting. In addition, all studies were sponsored by the manufacturers of the device.

In 2016, Englot et al. published a systematic review and meta-analysis to “elucidate rates and predictors of seizure freedom with VNS." The authors included 78 studies (n=2869), and data from the manufacturer's patient registry (n=5554). Registry data revealed a progressive increase over time in seizure freedom after VNS therapy. Overall, 49% of individuals responded to VNS therapy 0 to 4 months after implantation (≥50% reduction seizure frequency), with 5.1% of individuals becoming seizure-free, while 63% of individuals were responders at 24 to 48 months, with 8.2% achieving seizure freedom. On multivariate analysis, seizure freedom was predicted by age of epilepsy onset greater than 12 years (OR, 1.89; 95% CI, 1.38–2.58), and predominantly generalized seizure type (OR, 1.36; 95% CI, 1.01–1.82), while overall response to VNS was predicted by nonlesional epilepsy (OR, 1.38; 95% CI, 1.06–1.81). Systematic literature review results were consistent with the registry analysis: At 0 to 4 months, 40.0% of individuals had responded to VNS, with 2.6% becoming seizure-free, while at last follow-up, 60.1% of individuals were responders, with 8.0% achieving seizure freedom.

In 2017, Dibue-Adjei et al. published a meta-analysis of studies reporting seizure outcomes of individuals with Dravet syndrome (DS) treated with adjunctive VNS. The primary and secondary outcome measures were 50% or more reduction of seizures or of the most-debilitating seizure type and seizure reduction per individual. Thirteen studies comprising 68 individuals met the inclusion criteria of which 11 were single-center retrospective case series, one was a multicenter retrospective analysis and one was a case report. The reported fractions of individuals experiencing 50% or higher reduction varied between 0% and 100%, with a mean of 55.2% and a median of 50%. Because of different size of individual groups, the overall average responder rate was somewhat lower at 52.9%. Despite the low sample sizes of the included studies responder rates were similar in nearly all studies with more than six individuals with DS (75%, 67%, 50%, 38%, 50%, 38%). Seven of 13 studies reported additional benefits of VNS; however, this could not be assessed systematically. No conclusions on tolerability of VNS in individuals with DS can be made from this analysis, as in some studies adverse events were not reported for DS subpopulations, were not systematically assessed, or were not reported at all. However, hoarseness was the most frequently reported side-effect. The authors concluded that "vagus nerve stimulation appears to reduce seizure frequency in individuals with DS. Based on this preliminary analysis, controlled trials of VNS in this rare condition using patient-centric outcome measures are indicated."

Randomized Controlled Trials

Five RCTs (N=439) have evaluated VNS (Michael et al. 1993; Ben-Menchem et al./VNS Study Group 1994, 1995; Handforth et al. 1998; DeGiorgio et al. 2005; Klinkenberg et al. 2012). Four of the studies compared high-frequency VNS that was thought to be therapeutic versus low-frequency VNS at levels that were thought to be sub-therapeutic (Michael et al. 1993; Ben-Menchem et al./VNS Study Group 1994, 1995; Handforth et al. 1998; Klinkenberg et al. 2012). One study compared rapid versus medium versus slow cycle VNS (DeGiorgio et al. 2005). The studies generally included people with drug-resistant partial epilepsy with VNS as an add-on treatment. The blinded treatment phase ranged from 12 to 20 weeks in the 5 studies. Four studies reported the outcome of response (50% or greater reduction in seizure frequency) and the risk ratio ranged from 1.49 to 8.27 in the 3 studies (Michael et al. 1993; Ben-Menchem et al./VNS Study Group 1994, 1995; Handforth et al. 1998) that favored high-frequency VNS; the risk ratio was statistically significantly different from the null in 1 study. One study (Klinkenberg et al. 2012) reported a risk ratio that did not favor high-frequency VNS for the response outcome but was not statistically significant.

In 2014, Ryvlin et al. reported in an RCT the long-term quality of life outcomes for 112 individuals with medication-resistant focal seizures, which supported the beneficial effects of VNS for this group.

Observational Studies

The evidence for the efficacy of VNS for generalized seizures in adults is primarily from observational data, including registries and small cohort studies. Englot et al. (2016) examined freedom from seizure rates and predictors across 5554 individuals enrolled in the VNS Therapy Patient Outcomes Registry. The registry was established in 1999, after the 1997 FDA approval of VNS, and is maintained by the manufacturer of the device, LivaNova (formerly Cyberonics). Data were prospectively collected by 1285 providers from 978 centers (911 in the United States and Canada and 67 internationally) at preoperative baselines and various intervals during therapy. During active data collection, participation in the registry included approximately 18% of all implanted VNS devices. The database was queried in January 2015, and all seizure outcomes reported with the 0- to 4-, 4- to 12-, 12- to 24-, and 24- to 48-month time ranges after VNS device implantation were extracted and compared with patient preoperative baseline. Available information was tracked at each time point of data submission for the following outcomes: patient demographics, epilepsy etiology and syndrome, historical seizure types and frequencies, quality of life, physician global assessment, current antiepileptic drugs, medication changes, malfunctions, battery changes, and changes in therapy. At each observation point, responders were defined as having a 50% or greater decrease in seizure frequency compared with baseline and nonresponders as less than a 50% decrease. A localized epilepsy syndrome such as partial-onset seizures was recorded in 59% of the registry participants, generalized epilepsy in 27%, and 11% had a syndromic etiology (e.g., Lennox-Gastaut). From 0-4 months the responder rate and seizure freedom rate was 50% and 7%, respectively. At 4-12 and 12-24 months, 55% and 8%. At 24-48 months, approximately 60% and 9%. These rates did not differ statistically from participants with predominantly partial seizures.

In 2013, Garcia-Navarrete et al. evaluated outcomes after 18 months of follow-up for a prospective cohort of 43 individuals with medication-resistant epilepsy who underwent VNS implantation. Seizure types were heterogeneous, but 52% had generalized epilepsy. Pharmacotherapy was unchanged during the study. Twenty-seven (63%) individuals were described as “responders”, defined as having a 50% or greater reduction in seizure frequency compared with the year before VNS implantation. The difference in reduction of seizure frequency was not statistically significant between individuals with generalized and focal epilepsy.

The evidence for VNS for pediatric seizures consists of a variety of small noncomparator trials (Hornig et al. 1997; Patwardhan et al. 2000; Cukiert et al. 2013), prospective observational studies (Murphy et al. 1999; You et al. 2007), and retrospective case series (Frost et al. 2001; Healy et al. 2013; Terra et al. 2014; Yu et al. 2014). As in the adult studies, there is heterogeneity of seizure etiologies: mixed, syndromic, and idiopathic; there is also generalized and limited information on concomitant antiepileptic drug requirement. Some studies have defined pediatric individuals as less than 12 years of age and others have defined them as less than 18 years and may have included individuals as young as 2 to 3 years of age. Study subpopulations may have had prior failed resective surgery. Complete freedom from seizures is the exception, and the primary reported endpoint is 50% or more reduction in seizure frequency, determined over varying lengths of follow-up. There is an overlap of authors for multiple studies suggesting utilization of VNS in specialized clinical care environments. Multiple studies have some form of innovator device company sponsorship.

The evidence on the efficacy of VNS for treatment of medically refractory seizures consists of RCTs, meta-analyses, and numerous uncontrolled studies. RCTs and meta-analyses of RCTs have reported a significant reduction in seizure frequency with VNS for individuals with partial-onset seizures. The uncontrolled studies and case series have consistently reported reductions of clinical significance, defined as a 50% or more reduction in seizure frequency in both adults and children over almost 2 decades of publications. Interpretation of all outcomes and results were limited by the variety of comparators (when used), variability in length of follow-up, limited published data on antiepileptic medication requirements, mixed seizure etiologies, and history of prior failed resective surgery. There is an overlap of authors across multiple studies, suggesting utilization of VNS in specialized clinical care environments. Multiple studies have some form of innovator device company sponsorship.

REFRACTORY DEPRESSION
Systematic Reviews

Several systematic reviews and meta-analyses have assessed the role of VNS in treatment-resistant depression. A 2008 systematic review (Daban et al.) of the literature for VNS of treatment-resistant depression identified one randomized trial. VNS was found to be associated with a reduction in depressive symptoms in the open-label studies. However, results from the only double-blind trial were considered inconclusive. Daban et al. (2008) concluded that further clinical trials are needed to confirm efficacy of VNS in treatment-resistant depression.

In a meta-analysis that included 14 studies, Martin and Martin-Sanchez (2012) reported that, among the uncontrolled studies included in their analysis, 31.8% of subjects responded to VNS treatment. However, results from a meta-regression to predict each study’s effect size suggested that 84% of the observed variation across studies was explained by baseline depression severity. Berry et al. (2013) reported on results from a meta-analysis of 6 industry-sponsored studies of safety and efficacy for VNS in treatment-resistant depression, which included the D-01, D-02, D-03 (Bajbouj et al. [2010]), D-04, and D-21 (Aaronson et al. [2013]) study results. Also, the meta-analysis used data from a registry of individuals with treatment-resistant depression (335 individuals receiving VNS plus treatment as usual and 301 individuals receiving treatment as usual only) that were unpublished at the time of the meta-analysis publication (NCT00320372). The authors reported that adjunctive VNS was associated with a greater likelihood of treatment response (odds ratio, 3.19; 95% CI, 2.12 to 4.66). However, the meta-analysis did not have systematic study selection criteria, limiting the conclusions that can be drawn from it.

In 2018, Bergfeld et al. published a study whose purpose was to estimate attempted and completed suicide incidences in individuals with treatment-resistant depression (TRD) irrespective of treatment and estimate whether specific treatments might increase or decrease these incidences. Thirty studies were included, however, 9 of 30 studies assessed VNS therapy (n=1,945). The completed suicide incidence was 2.01 (0.84–4.85) in DBS (deep brain stimulation) studies, 0.33 (0.10–1.13) in VNS studies, and 0.78 (0.13–4.84) in ECT (electroconvulsive therapy) studies. None of the treatments increased or decreased suicide incidences in a statistically significant way (QM (2)=3.1, P=0.22). The attempted suicide incidence was 5.58 (3.19–9.87) in DBS studies, and 4.85 (3.25–7.32) in VNS studies (effect of treatment: QM(1)=0.1, P=0.74).

In 2019, Bottomley et al. published a systematic review whose purpose was to provide an up-to-date comprehensive SLR (systematic literature review) and meta-analysis of all studies of adjunctive VNS in treatment-resistant depression (TRD), including recent much longer-term experience of VNS. Of 22 identified studies, there were two RCTs, 16 single-arm and 4 non-randomized comparative studies. Numerous depression-specific, safety and QOL measures were reported. Meta-analysis was possible for three efficacy (Montgomery-Åsberg Depression Rating Scale [MADRS], Clinician Global Impression-Improvement, Hamilton Rating Scale for Depression) and three safety (serious adverse events, study drop-outs and all-cause mortality) but no QOL measures. Data beyond 2 years was not poolable. Analyses demonstrated that antidepressant benefits improved to 24 months and safety issues were minimal. Heterogeneity was high and statistically significant. The authors concluded that "despite limitations in the evidence base, our comprehensive summary of VNS+TAU outcomes suggests that this treatment provides improving benefit and hope for this very hard-to-treat chronic population. More comparative TRD studies should describe safety and QOL."

Randomized Controlled Trials

One randomized study (D-02) that compared VNS therapy with a sham control (implanted but inactivated VNS) showed a nonstatistically significant result for the principal outcome (Rush et al. 2005; FDA Summary of Safety and Effectiveness Data 2005). Fifteen percent of VNS subjects responded versus 10% of control subjects (p=0.31). The Inventory for Depressive Symptomatology Systems Review score was considered a secondary outcome and showed a difference in outcome that was statistically significant in favor of VNS (17.4%) compared with sham treatment (7.5%; p=0.04).

Rush et al. (2005) reported results of a 10-week, blinded RCT comparing adjunctive VNS with sham in 235 outpatients with nonpsychotic major depressive disorder or nonpsychotic, depressed phase, bipolar disorder. The individuals were treatment-resistant defined as those who had not responded adequately to between 2 and 6 research-qualified medication trials for the current episode of depression. The primary outcome was response rates (50% or more reduction from baseline on the Hamilton Rating Scale for Depression). There was no statistically significant difference in response rates at 10 weeks in VNS versus sham (15% vs. 10%; p=0.25).

Aaronson et al. (2013) reported on results from an active-controlled trial in which 331 individuals with a history of chronic or recurrent bipolar disorder or major depressive disorder, with a current diagnosis of a major depressive episode, were randomized to 1 of 3 VNS current doses (high, medium, low). Individuals had a history of failure to respond to at least 4 adequate dose/duration of antidepressant treatment trials from at least 2 different treatment categories. After 22 weeks, the current dose could be adjusted in any of the groups. At follow-up visits 10, 14, 18, and 22 weeks after enrollment, there were no statistically significant differences between the dose groups for the study’s primary outcome, change in Inventory of Depressive Symptomatology (IDS) score from baseline. However, mean IDS scores improved significantly for each group from baseline to the 22-week follow-up. At 50-week follow-up, there were no significant differences between the treatment dose groups for any of the depression scores used. Most individuals completed the study; however, there was a high rate of reported adverse events, including voice alteration in 72.2%, dyspnea in 32.3%, and pain in 31.7%. Interpretation of the IDS improvement over time is limited by the lack of a no-treatment control group. Approximately 20% of the individuals included had a history of bipolar disorder; as such, the results might not be representative of most individuals with treatment-resistant unipolar depression.

Prospective Observational Studies

The observational study that compared individuals participating in the RCT with individuals in a separately recruited control group (D-04 vs. D-02, respectively) evaluated VNS therapy out to 1 year and showed a statistically significant difference in the rate of change of depression score (George et al. 2005; FDA Summary of Safety and Effectiveness Data 2005). However, issues such as unmeasured differences among individuals, nonconcurrent controls, differences in sites of care between VNS therapy individuals and controls, and differences in concomitant therapy changes raise concern about this observational study. Analyses performed on subsets of individuals cared for in the same sites, and censoring observations after treatment changes, generally showed diminished differences in apparent treatment effectiveness of VNS and almost no statistically significant differences (De Ferrari et al. 2011). Patient selection for the randomized trial and the observational comparison trial may be of concern. VNS is intended for treatment-refractory depression, but the entry criteria of failure of 2 drugs and a 6-week trial of therapy might not be a strict enough definition of treatment resistance. Treatment-refractory depression should be defined by thorough psychiatric evaluation and comprehensive management. It is important to note that patients with clinically significant suicide risk were excluded from all VNS studies. Given these concerns about the quality of the observational data, these results did not provide strong evidence for the effectiveness of VNS therapy.

Aaronson et al. (2017) reported on results from the FDA required post-marketing surveillance study, which was a 5-year, prospective, open-label, nonrandomized observational study of the Treatment-Resistant Depression Registry. The study compared treatment as usual, with or without adjunctive VNS. It was conducted at 61 sites in the United States and included 795 individuals (VNS n=494, no VNS n=301) who were experiencing a major depressive episode (unipolar or bipolar depression) of at least 2 years’ duration or had a history of 3 or more depressive episodes (including the current episode), and who had failed at least 4 prior depression treatments (including electroconvulsive therapy). Study treatment was patient-selected and/or assigned on an individualized basis at the discretion of the study site. The exception was for a subset of 159 (32%) of individuals with VNS who were rolled over from the D-21 study (described above). (Aaronson et al. 2013) The primary efficacy outcome was the cumulative first-time 5-year response rate, defined as at least a 50% reduction in the MADRS score at any post-baseline visit. Due to its nonrandomized design, several significant between-groups differences were noted at baseline, including that the VNS group had a higher rate of past treatment with electroconvulsive therapy (57% vs. 40%; p<.001), a higher number of prior failed depression treatments (8.2 vs. 7.3; p=.010) more psychiatric hospitalizations within the 5 years before enrollment (3.0 vs. 1.9; p<.001) and lifetime suicide attempts (1.8 vs. 1.2; p=.02), and a higher mean MADRS score (33.1 vs. 29.3; p<.001). The propensity score method was used to adjust for these baseline imbalances. Clinical outcomes were significantly improved in the VNS groups, including higher cumulative first-time response (67.6% vs. 40.9%; p<.001) and cumulative first-time remission (MADRS total score ≤ 9 at any postbaseline visit, 43.3% vs. 25.7%; p<.001). The VNS arm also demonstrated a significantly greater reduction in suicidality on 2 of 3 different measures: Quick Inventory of Depressive Symptomatology–Self Report (QIDS-SR) item 12 (OR=2.11; 95% CI, 1.28 to 3.48), investigator-completed suicidality assessment (OR=2.04; 95% CI, 1.08 to 3.86), but not MADRS item 10 (OR=1.67; 95% CI, 0.98 to 2.83). There was no significant difference between the VNS and no VNS groups in completed suicides (1.01 per 1,000 person-years [95% CI=0.11 to 3.64] and 2.20 per 1,000 person-years [95% CI=0.24 to 7.79], respectively). Important limitations of the study include lack of a sham condition and the potential for bias due to confounding from unrestricted and uncontrolled concomitant treatments and bias in outcome measurement, which was unblinded. Additionally, other important outcomes such as quality of life and relapse were not reported.

In 2020, McAllister-Williams et al. reported on results of a subgroup of 156 participants with treatment-resistant bipolar depression from the above-described FDA-required post-marketing surveillance study (Aaronson et al [2017]). Compared to the overall population in the primary study, cumulative first-time response rates were similar in this bipolar depression subgroup (63% vs. 39%; p not reported). Median time-to-initial response was not significantly different between groups (13.7 vs. 42.1 months; Hazard Ratio [HR]=1.7; 95% CI, 1 to 2.7). Median time-to-relapse from initial response in the first year was also not significantly different between groups (15.2 vs. 7.6 months; HR=0.7; 95% CI, 0.3 to 1.4). Based on MADRS item 10, the mean reduction in suicidality score across the study visits was reportedly significantly greater in the VNS group than in the no VNS group (p<.001 as per F-test). However, the validity of this finding is unclear as by 60 months, it excluded data from an unacceptably high (n=100, 64%) and imbalanced (59% in VNS group vs. 73% in no VNS group) number of individuals with unavailable suicidality data. It was additionally subject to the same important limitations as described above for the primary study.

Case Series

Several case series (Marangell et al. 2002; Rush et al. 2000; Sackeim et al. 2001) published before the randomized trials showed rates of improvement with VNS, as measured by a 50% improvement in depression score, of 31% at 10 weeks to greater than 40% at 1 to 2 years, but there were some losses to follow-up. Natural history, placebo effects, and patient and provider expectations make it difficult to infer efficacy from case series data.

Other case series do not substantially strengthen the evidence supporting VNS. A case series by Bajbouj et al. (2010), which followed individuals for 2 years, showed that 53.1% (26/49) met criteria for treatment response and 38.9% (19/49) met criteria for remission. A small 2008 study (Marangell et al.) of 9 patients with rapid-cycling bipolar disorder showed improvements in several depression rating scales over 40 weeks of observation. In a 2014 case series (Tisi et al.) that included 27 patients with treatment-resistant depression, 5 patients demonstrated complete remission after 1 year, and six individuals were considered responders.

Adverse events of VNS therapy included voice alteration, headache, neck pain, and cough, which are known from prior experience with VNS therapy for seizures. Regarding specific concerns for depressed individuals (e.g., those with mania, hypomania, suicide, or worsening depression), there does not appear to be a greater risk of these events during VNS therapy (FDA Summary of Safety and Effectiveness Data 2005).

On July 15, 2005, the FDA approved the VNS Therapy System, NeuroCybernetic Prosthesis (NCP®) System (LivaNova USA, Inc., formerly Cyberonics, Inc., Houston, TX) for use as an adjunctive long-term treatment for chronic or recurrent depression in individuals 18 years of age or older who have experienced a major depressive episode and have not adequately responded to four or more antidepressant treatments. Despite FDA approval, current published peer-reviewed literature does not support the use of VNS for the treatment of depression. The clinical trials for the use of VNS for treatment-resistant depression (TRD) do not demonstrate the effectiveness of VNS therapy on health outcomes in an investigational setting, nor do these trials demonstrate improved health outcomes with the use of VNS when compared to other treatment modalities for TRD. Additional research is recommended. 

OTHER CONDITIONS
VNS therapy has also been investigated for use in other conditions; however, the available published peer-reviewed evidence is limited and not sufficient to permit conclusions of effectiveness.

Chronic Heart Failure

Systematic Reviews
Sant'Anna et al. (2021) conducted a systematic review and meta-analysis on clinical trials comparing VNS with medical therapy for the management of chronic heart failure with reduced ejection fraction. Four RCTs and 3 prospective studies were identified (N=1263). Only data from the 4 RCTs were included in the meta-analysis. The certainty of the evidence based on GRADE characteristics was reported as high for all outcomes. The meta-analysis found significant improvements in New York Heart Association functional class, quality of life, 6-minute walk test, and N-terminal-pro brain natriuretic peptide levels in individuals treated with VNS compared to sham.

Case Series
In a study examining the safety and efficacy of VNS in individuals with chronic heart failure, De Ferrari et al. (2011) showed improvements in New York Heart Association (NYHA) class quality of life, six-minute walk test, and left ventricular ejection fraction; however, these findings require confirmation in controlled clinical trials. The Autonomic Neural Regulation Therapy to Enhance Myocardial Function in Heart Failure With Preserved EjectionFraction (ANTHEM-HF) trial (Premchand et al. 2014) is another case series, but in it, individuals were randomly assigned to right- or left-sided vagus nerve implantation (but without a control group). Overall, from baseline to 6-month follow-up, a number of measures were improved: LV ejection fraction improved by 4.5% (95% CI, 2.4% to 6.6%); LV end-systolic volume improved by -4.1 mL (95% CI, -9.0 to 0.8 mL); LV end-diastolic diameter improved by -1.7 mm (95% CI, -2.8 to -0.7 mm); heart rate variability improved by 17 ms (95% CI, 6.5 to 28 ms); and 6-minute walk distance improved by 56 meters (95% CI, 37 to 75 meters). A follow-up analysis to ANTHEM-HF by Nearing et al. (2021) evaluated outcomes of VNS at 12, 24, and 36 months.49, They found that LV ejection fraction improved by 18.7% (p=.008), 19.3% (p=.04), and 34.4% (p=.009) at 12, 24, and 36 months, respectively, with high-intensity VNS. Individuals with low-intensity VNS only had significant improvement in LV ejection fraction at 24 months (12.3%; p=.04).

Zannad et al. (2015) reported on results from the NEural Cardiac TherApy foR Heart Failure (NECTAR-HF) RCT, a randomized, sham-controlled trial, with outcomes from VNS in patients with severe LV dysfunction despite optimal medical therapy. Ninety-six individuals were implanted with a vagal nerve stimulator and randomized in a 2:1 manner to active therapy (VNS ON) or control (VNS OFF) for 6 months. Programming of the generator was performed by a physician unblinded to treatment assignment, while all other investigators and site study staff involved in the endpoint data collection were blinded to randomization. Sixty-three patients were randomized to the intervention, of whom 59 had paired pre-post data available, while 32 were randomized to control, of whom 28 had paired data available. The analysis was a modified intention-to-treat. For the primary endpoint of change in LV end-diastolic diameter from baseline to 6 months, there were no significant differences between groups (p=0.60 between-group difference in LV end-diastolic diameter change). Other secondary efficacy endpoints related to LV remodeling parameters (i.e., LV function and circulating biomarkers of heart failure) did not differ between groups, with the exception of 36-Item Short-Form Health Survey Physical Component Summary score, which showed greater improvement in the VNS ON group than in the control group (from 36.3 to 41.2 in the VNS ON group vs. from 37.7 to 38.4 in the control group; p=0.02). Subject blinding was found to be imperfect, which might have biased the subjective outcome data reporting. 

The evidence on VNS for treatment of chronic heart failure consists of a systematic review including 4 RCTs and 2 uncontrolled studies. A meta-analysis of 4 RCTs found significant improvements in New York Heart Association functional class, quality of life, 6-minute walk test, and N-terminal-pro brain natriuretic peptide levels in individuals treated with VNS compared to sham. The uncontrolled studies consistently reported improvements on a variety of measures, including LV function, 6-minute walk test and quality of life. However, lack of a no-VNS comparator group precludes drawing conclusions based on findings from the uncontrolled studies.

Essential Tremor

Handforth et al. (2003) studied VNS in nine individuals with essential tremor resulting in no improvement in upper extremity tremors. The authors of the study reported that VNS is not likely to have any clinically meaningful effect in essential tremor treatment.

Fibromyalgia

VNS has been investigated for use in fibromyalgia. Lange et al. (2011) conducted a single-arm Phase I/II trial of 14 individuals with fibromyalgia. At three months, five individuals met criteria for improvement of symptoms, at 11 months, eight individuals met efficacy criteria. However, the results do not provide sufficient evidence for use of VNS for fibromyalgia. 

Headache/Migraine

Vagal nerve stimulation is being studied for treating chronic headaches. Mauskop (2005) evaluated VNS in five individuals with severe, refractory chronic cluster and migraine headaches. One individual had excellent results with regaining the ability to work, and two individuals reported significant improvement of their headaches. Small sample size prevents drawing conclusions on the effects of VNS for the treatment of headache.

Obesity

On January 14, 2015, the FDA approved the MAESTRO® Rechargeable System (EnteroMedics, St. Paul, MN), consisting of a rechargeable neuroregulator device implanted into the lateral chest wall with flexible leads placed laparoscopically around the vagus nerve, for use in weight reduction in individuals aged 18 years through adulthood who have a Body Mass Index (BMI) of 40 to 45 kg/m2, or a BMI of 35 to 39.9 kg/m2 with one or more obesity-related co-morbid conditions, and have failed at least one supervised weight management program within the past five years. The approval is based on a 12-month randomized, double-blind, sham controlled clinical trial involving 239 participants. Despite FDA approval, several limitations in this study include the use of vagal nerve block compared with a sham control device did not meet either of the pre-specified co-primary efficacy objectives. The co-primary effectiveness endpoints were to determine whether the vagal nerve block was superior in mean percentage excess weight loss to sham by a 10-point margin with at least 55% of individuals in the vagal block group achieving a 20% loss and 45% achieving a 25% loss, even though weight loss in the vagal block group was greater than in the sham device group. In addition, the treatment arm participants could possibly feel the stimulation device, while the control arm doesn’t feel anything, so individuals may lose motivation to participate and not adhere to diet program, which would limit their weight loss, causing weight loss in the vagal block group to be greater than in the sham device group. Because the study did not compare outcomes with established surgical obesity treatments (e.g., gastric banding, Roux-en Y gastric bypass), because of the short-term follow-up period without long-term outcomes of vagal nerve stimulation for morbid obesity, at this time there is inadequate data to permit scientific conclusions regarding the efficacy of this procedure.

The commercial availability of the MAESTRO® Rechargeable System is unclear. On the FDA's Weight-Loss and Weight-Management Devices webpage (content noted as current as of 04/27/2020), the Maestro® Rechargeable System is described as "no longer marketed as of September 2018". Additionally, on the ReShape LifesciencesTM website (previously EnteroMedics), the MAESTRO® Rechargeable System, is not listed among their current portfolio of medical devices to treat obesity and metabolic disease. However, updates to the MAESTRO® Rechargeable System were noted in the FDA Premarket Approval database (P130019) subsequent to September 2018, including updates to the circuit assembly and application firmware of the mobile charger (01/25/2019) and approval of modifications to the follow-up schedule for the post-approval study protocol.

Bodenlos et al (2007) suggested that VNS might affect food cravings of individuals with chronic, treatment-resistant depression and thus induce weight loss in obese individuals. Several limitations in the study such as small sample size, lack of randomization, heterogeneity of groups with respect to depression, prevent drawing conclusions about the impact of VNS on eating behavior. The study findings need to be validated in large, well-designed controlled studies to evaluate the impact of VNS on eating behavior and obesity.

The published literature on VNS for obesity consists of 2 randomized, controlled trials (RCTs), both of which were industry-sponsored, multicenter, double-blind, and sham-controlled (Sarr et al, 2012; Ikramuddin et al, 2014). Although both trials included a sham treatment group, protocols differed. In the 2012 Vagal Blocking for Obesity Control (EMPOWER) trial (Sarr et al, 2012), all participants [n=294] had devices implanted and leads placed. However, external controllers were programmed differently such that if the controllers were worn for 10 hours a day, the total charge delivered was 3.9 coulombs (C) to individuals in the treatment group [n=192 to active Maestro® device plus 15 weight management counseling sessions] and a negligible amount (0.0014 C), to the sham group [n=102 to inactive Maestro® device plus 15 weight management counseling sessions]. In the 2014 trial (Ikramuddin et al, 2014) to Evaluate the Safety and Efficacy of vBloc Therapy Delivered by the Maestro® Rechargeable System for the Treatment of Obesity (ReCharge), all participants (n=239) had devices implanted [n=162 to active sham Maestro® device plus 17 weight management counseling sessions], but no leads were placed in the sham group [n=77 to inactive sham Maestro® device plus 17 weight management counseling sessions].

The primary efficacy outcomes were not met in either RCT. The difference in mean percent excess weight loss (EWL) was the sole primary efficacy outcome in the Vagal Blocking for Obesity Control (EMPOWER) study and a coprimary outcome in the Evaluate the Safety and Efficacy of vBloc Therapy Delivered by the MaestroRechargeable System for the Treatment of Obesity (ReCharge) study. This outcome was evaluated in both trials using a superiority margin of 10% (i.e., the efficacy objective would be met only if there was a >10% difference between groups in EWL). FDA documents (Summary of Safety and Effectiveness Data (SSED): Maestro Rechargeable System, 2015) have indicated the unattained 10% margin was considered to indicate a clinically meaningful difference in weight loss between active and sham treatment groups.

For the ReCharge trial, however, in addition to the primary efficacy analysis, the authors conducted a post hoc analysis that evaluated the difference in EWL between groups using a 2-sided t-test with no superiority margin. In this post hoc analysis, the difference between groups (8.5% EWL; 95% confidence interval [CI], 3.1% to 13.9%) was statistically significant. (The difference between groups in percent EWL in the Vagal Blocking for Obesity Control (EMPOWER) study was 1%.)

The outcome used in these studies was percent EWL, and modest changes in this outcome may translate to a relatively small amount of weight loss relative to total weight for individuals with morbid obesity. Mean initial body weight in the Evaluate the Safety and Efficacy of vBloc Therapy Delivered by the Maestro Rechargeable System for the Treatment of Obesity (ReCharge) trial was 113 kilograms (249 pounds) in the active treatment group and 116 kilograms (255 pounds) in the sham group. Mean excess body weight was 44 kilograms (97 pounds) in the treatment group and 45 kilograms (99 pounds) in the sham group. Thus, a difference of 10% EWL, used in the primary analyses, represents a difference of only about 5 kilograms (10 pounds) in absolute weight loss and a 4% difference in absolute body weight.

The Evaluate the Safety and Efficacy of vBloc Therapy Delivered by the Maestro Rechargeable System for the Treatment of Obesity (ReCharge) study had a second primary outcome, which would have been met if at least 55% of individuals in the active treatment group had achieved at least 20% EWL and at least 45% had achieved at least 25% EWL. This outcome was not achieved; the data showed that 52% of individuals in the active treatment group achieved at least 20% EWL and 38% achieved at least 25% EWL. In the Vagal Blocking for Obesity Control (EMPOWER) study, groups did not differ significantly on the secondary outcome measure (percent of individuals achieving at least 25% EWL).

In post hoc subgroup analysis of the Vagal Blocking for Obesity Control (EMPOWER) trial, longer duration of device use per day was associated with a larger percent EWL. However, this improvement occurred in the sham group as well as the active treatment group. For example, percent EWL among individuals who used the device for less than 6 hours a day was 5% in the active treatment group and 6% in the sham group, whereas percent EWL among individuals who used the device for at least 12 hours a day was 30% and 22%, respectively. This finding suggests a substantial placebo effect associated with device use.

Both trials met their primary safety outcomes, which related to serious adverse events. However, there were frequent nonserious adverse events. Most were of mild or moderate severity.

Additional information on the ReCharge trial design and findings has been reported in the FDA documents (Summary of Safety and Effectiveness Data (SSED): Maestro Rechargeable System, 2015). The trial was designed to evaluate primary endpoints at 12 months and to follow individuals to 5 years postimplant. Individuals were blinded until 12 months and unblinding began once all individuals had completed the 12-month follow-up. After the 12-month follow-up, sham individuals had the option to cross over into the active treatment group. At 18 months, follow-up data (n=159) were reported for 117 (72%) individuals initially assigned to the active treatment group and 42 (55%) assigned to the sham treatment group. The number of individuals in the sham group who crossed over to active treatment and the timing of unblinding was not reported. At 18 months, the mean percent EWL was 25.3% in the active treatment group and 11.7% in the sham group; the mean between-group difference was 13.5% (95% CI, 5.7% to 21.3%). In this analysis, the treatment group maintained the weight loss they achieved at 12 months, and the control group gained weight. Nearly half of the patients initially randomized to the sham group were not included in the 18-month analysis, which limits the ability to draw conclusions about these data. In addition, the 18-month analysis could have been biased by unblinding, which occurred after all individuals completed the 12-month follow-up. In the 12-month sham intervention phase of the trial, individuals in both groups experienced decreased hunger, increased cognitive restraint, and decreased food intake. It is likely that unblinding could have had an impact on these factors. The FDA documents also reported longer-term safety data. Analyses of data up to 48 months from the Vagal Blocking for Obesity Control (EMPOWER) trial and 18-month data from the ReCharge trial did not identify any deaths or unanticipated serious adverse events. There were 13 surgical explants through 12 months (5 in the active treatment group, 8 in the sham group) and an additional 16 explantations between 12 and 18 months. Reasons for explant included the patient decision, pain, and need for magnetic resonance imaging (MRI).

Eighteen-month follow-up data from the ReCharge trial were published by Shikora et al. (2015). They reported on a larger proportion of the patient population than that discussed in the FDA documents: in addition to the 159 (67%) of 239 randomized individuals who completed the 18-month follow-up, the 2015 analysis included 30 individuals who missed the 18-month analysis but had a visit at 16 or 17 months. The additional individuals included 11 from the active treatment group and 19 from the sham group, comprising 188 individuals (79% of those originally randomized). At 18 months, the mean percent EWL noted was 23.5% (95% CI, 20.8% to 26.3%) in the active treatment group and 10.2% (95% CI, 6.0% to 14.4%) in the sham group. The mean between-group difference in percentage EWL was 13.4% (95% CI, 8.4% to 18.4%). The authors also evaluated the potential impact of blinding on outcomes and found no statistically significant effect; their findings were similar to the analysis restricted to individuals who remained blinded at 18 months. The percentages of EWL at 18 months in this 2015 analysis of ReCharge trial data were also like those previously reported in the FDA documents, although this sample size was larger, reducing potential bias from missing data. However, because this post hoc analysis incorporated 16- and 17-month data in addition to 18-month data, the authors considered these results preliminary or hypothesis-generating.

Twenty-four-month outcomes from the ReCharge trial were published by Apovian et al. (2017). The investigators noted that the sham arm was no longer a valid comparator at 24 months due to crossovers, dropouts, and patient unblinded at 12 months. There was no prespecified statistical analysis plan for assessments after the 12-month primary outcome assessment, including those in this 2017 article. A total of 103 (43%) individuals of 239 randomized individuals completed the 24-month follow-up. Their mean EWL was 21% (95% CI, 16% to 26%) and mean total weight loss was 8% (95% CI, 6% to 10%). No serious treatment-related adverse events were reported in the 18- to 24-month time period. The analysis lacked a blinded comparison group, and, like the 18-month data, was post hoc.

In 2016, a position statement published by the American Society for Metabolic and Bariatric Surgery (Papasavas et al. 2016) included the following conclusions on VNS for the treatment of obesity:

  1. ​Reversible vagal nerve blockade has been shown to result in statistically significant EWL [excess weight loss] at 1 year compared with a control group in one of 2 prospective randomized trials.
  2. Reversible vagal nerve blockage has been shown to have a reasonable safety profile with a low incidence of severe adverse events and a low revisional rate in the short term. More studies are needed to determine long-term reoperation and explantation rates.
  3. The prospective collection of VBLOC [vagus nerve blocking] outcomes as part of the national center of excellence databases is encouraged to establish the long-term efficacy of this new technology.”
In 2018, the U.S. Preventive Services Task Force (USPSTF) updated recommendations for screening and management of obesity in adults (Curry et al. 2018). The Task Force recommended screening all adults for obesity and referring those with a body mass index of 30 kg/m2 or higher to intensive, multicomponent behavioral interventions. VNS and other surgical interventions were not addressed in the recommendations or literature review.

Obsessive-Compulsive Disorder (OCD)

In 2017, Cimpianu et al. published a systematic review evaluating the available evidence of the efficacy of VNS for the treatment of psychiatric disorders. Data derived from animal models, experimental trials without health-related outcomes, case reports, single-session studies, and reviews were excluded. From 1292 publications, 33 records were included for further analyses: 25 focused on VNS as treatment of unipolar or bipolar major depressive disorder and one investigated the neurocognitive improvement after VNS in major depressive disorder. Seven focused on the improvement of cognitive function in Alzheimer´s disease, improvement of schizophrenia symptoms, treatment of obsessive compulsive disorder (OCD), panic disorder (PD) and post-traumatic stress disorder (PTSD), treatment resistant bipolar disorder, treatment of fibromyalgia, and Prader-Willi syndrome. A total of 29 studies used invasive VNS, while four studies used non-invasive, transcutaneous VNS. Only 7 out of 33 studies investigated conditions other than affective disorders. The efficacy data of VNS in affective disorders is promising, whereas more in controlled and naturalistic studies are needed. In other conditions like schizophrenia, Alzheimer's disease, OCD, PD, PTSD, and fibromyalgia, either no effects or preliminary data on efficacy were reported. The authors concluded that "no final conclusion can be made regarding the efficacy of VNS to improve symptoms in psychiatric disorders other than in affective disorders".

Tinnitus

The clinical efficacy of VNS on tinnitus was studied by De Ridder et al. (2014) in a case series involving 10 individuals that suggests that VNS may be associated with clinical improvements in individuals with tinnitus. The findings of this study need to be validated in large, well-designed controlled studies to evaluate the impact of VNS on tinnitus.

Traumatic Brain Injury

Currently, VNS is being investigated to augment recovery from a traumatic brain injury. It is proposed that early stimulation of the vagus nerve accelerates the rate and extent of behavioral and cognitive recovery after fluid percussion brain injury in rats. Shi et al. (2013) received FDA approval to conduct a pilot prospective randomized trial to demonstrate objective improvement in clinical outcome by placement of a VNS in individuals who are recovering from severe traumatic brain injury. If this study demonstrates that VNS can safely and positively impact outcome, then a larger randomized prospective crossover trial will be proposed. 

Upper-Limb Impairment Due To Stroke

VNS-REHAB studies:
A feasibility study demonstrated that the Vivistim System improved upper limb function with no significant device complications (Dawson et al., 2016). A non-implant control group and Cyberonics (LivaNova) Lead was utilized for this study (Dawson et al., 2016). A MicroTransponder Lead was designed for the next pilot study that looked at outcomes of VNS when provided in the home and clinic to determine VNS paired with rehabilitation was acceptably safe and feasible in participants with upper limb motor deficit after chronic ischemic stroke (Kimberley et al., 2018). The VNS group (n=8) showed greater improvement in function compared to the control group (n=9) for individuals with chronic stroke (anywhere from 4 months and 5 years post-stroke). One year follow-up data from the pilot study showed no VNS treatment-related serious adverse events (Dawson et al., 2020). 

In the VNS-REHAB randomized sham-controlled trial, participants with moderate to severe arm weakness, at least 9 months after ischemic stroke, were assigned to receive rehabilitation paired with active VNS (n=53) or rehabilitation paired with sham stimulation (Control) (n=55) (Dawson et al., 2021). All participants were implanted with a VNS device and received six weeks of in-clinic therapy followed by a home exercise program. The primary outcome was the change in impairment measured by the Fugl-Meyer Assessment Upper Extremity (FMA-UE) score on the first day after completion of in-clinic therapy. The secondary outcomes measures were 1) clinically meaningful response on FMA-UE score at day 90, 2) change in day 90 WMFT-Functional and FMA-UE score. The researchers defined a clinically meaningful response as a six 6 point or greater improvement in FMA-UE score based on previous research (Page et al., 2012).

The primary outcome (change in FMA-UE score from baseline to the first day after in-clinic therapy) was significantly higher in the VNS group than the Control group (VNS: 5.0, SD 4.4, Control: 2.4, SD 3.8; p=0.001; between group difference 2.60, 95% CI 1.03 to 4.2) (Dawson et al., 2021). A clinically meaningful response on the FMA-UE score occurred in more participants in the VNS group compared to the control group at day 90 following completion of in-clinic therapy (47% versus 24%, p=0.01; between group difference 24%, 95% CI 6 to 41%) (Dawson et al., 2021).

The FMA-UE score was also significantly increased in the VNS group compared to the Control group at 90 days (VNS: 5.8, SD 6.0, Control: 2.8, SD 5.2; p=0.008; between group difference 2.96, 95% CI 0.83 to 5.08) (Dawson et al., 2021). Similar was found for the WMFT-Functional score at 90 days after the end of clinic therapy (VNS: 0.46, SD 0.40, Control: 0.16, SD 0.30; between group difference 0.30, 95% CI 0.16 to 0.43) (Dawson et al., 2021). Participants were unblinded after the day-90 follow up and controls then received VNS, meaning that any long-term data will lack a control comparator.

A total of 334 adverse events (163 VNS, 171 Control) were reported in 85 (78%) participants, where the majority were mild (Dawson et al., 2021). A total of 21 (40%) participants in the active VNS group and 24 (55%) controls reported an adverse event rated that were at least possibly, probably, or definitely related to surgery/device implantation (Dawson et al., 2021). The most common AE associated with the surgery was pain (22 %; 6 possible, 3 probable, 13 definite). Surgery-related adverse events occurred at rates lower than previously reported VNS therapy for epilepsy and depression (Liu et al., 2022). 

Post-hoc analyses: 
A post-hoc analysis of the VNS-REHAB RCT showed the response to VNS treatment was similar across subgroups (e.g., age (≥62 years), time from stroke (>2 years), severity (baseline FMA-UE score >34)) (Dawson et al., 2023). Another post-hoc analysis of the VNS-REHAB RCT showed VNS paired with rehabilitation resulted in significant improvements in specifically wrist and hand impairment compared to control (Lin et al., 2024). Another post-hoc analysis of the VNS-REHAB RCT found that dosing parameters (time over which task repetitions were executed and number of VNS stimulations) were not associated with FMA-UE responder status at the end of 6 weeks (Beovich et al., 2024). The most recent post-hoc analysis of the VNS-REHAB RCT found that neuroimaging measures were associated with the extent of gains on the primary endpoint across all individuals (n=80) where less white matter hyperintensities (r = -0.25, p = 0.028) at baseline was associated with a larger Fugl-Meyer score change (Schwarz et al., 2025). Similarly, an exploratory analysis of the pilot and feasibility data showed higher cerebrospinal fluid volume was associated with less improvement in FMA-UE in the control but not VNS group (Dickie et al., 2019). A secondary analysis of the VNS-REHAB trial, reported that paired-VNS improved distal UE impairment in chronic stroke to a greater degree than intensive rehabilitation alone, but proximal improvements were equally responsive to either treatment (Vora et al., 2024). Other post-hoc analyses suggests that the effect of VNS observed in the VNS-REHAB trial are likely to be consistent in a wide range of stroke survivors with moderate to moderately severe upper extremity impairment; however, this should be clarified by further studies (Dawson et al., 2023; Kimberley et al., 2025).

Kimberley et al. (2025) conducted an unblinded, partial crossover, pooled 1-year post hoc analysis of data from the fully blinded, sham-controlled VNS-REHAB trial. The study evaluated the long-term effects of VNS paired with upper extremity rehabilitation in individuals with chronic ischemic stroke occurring 9 months to 10 years prior to enrollment. Participants received 18 sessions of intensive, task-specific rehabilitation (3x/week for 6 weeks) and 3 months of self-directed home exercise, with either active (n=53) or sham (n=55) VNS. After the blinded phase, control participants crossed over to active VNS. All participants continued self-initiated VNS therapy for one year. Outcome measures were assessed using the Fugl-Meyer Assessment UE (FMA-UE), Wolf Motor Function Test (WMFT), and patient-reported outcomes including Motor Activity Log (Quality of Movement and Amount of Use), Stroke Impact Scale (Activities of Daily Living and Hand), EQ-5D, and Stroke-Specific Quality of Life. At 1-year follow-up, 74 participants (69%) completed the observation phase and showed significant improvements across all measures. Four serious adverse events (dyspnea, infection, acute infarct) occurred post-blinded phase and were deemed unrelated to the intervention (3 in VNS group, 1 in control). Study limitations included participant attrition, unblinding, incomplete data reporting, lack of diversity metrics, unmonitored home exercise adherence, small sample size, and short follow-up duration.

Meta-analysis/systematic reviews:
Two meta-analyses determined VNS may be an effective and safe adjunct to standard rehabilitation for post-stroke recovery; however, its clinical significance and long-term efficacy and safety remain unclear (Ananda et al., 2023; Zhao et al., 2022). Another meta-analysis suggested that VNS and rehab was no better than rehab on mental health or activities of daily living. Combinations of phase of stroke, specific parameters of VNS and VNS intervention frequency highly influenced outcomes (Gao et al., 2023). 

Another meta-analysis analyzed eight RCTs involving 266 individuals where five studies used direct VNS and three transcutaneous auricular VNS. The results revealed that VNS enhanced upper extremity function via FMA-UE (SMD = 0.73; 95% CI: 0.48 to 0.99; P < 0.00001) and WMFT (SMD = 0.82; 95% CI:0.52 to 1.13; P < 0.00001) in comparison to the control group but showed no significant change on long-term effects of FMA-UE. More high-quality multicentric RCTs are needed to validate this conclusion (Wei et al., 2023). 

However, these meta-analyses on VNS have inappropriately combined studies of fundamentally different interventions, outcome measures, and participant selection, which do not conform to methodological best practices and, hence, cannot be used to deduce the relative efficacy of the different types of VNS for stroke rehabilitation (Malakouti et al., 2024). All the above-mentioned review papers combined results of non-implantable (transcutaneous auricular) and implantable VNS, misrepresenting the exact effects implantable VNS itself. 

Another systematic review concluded that there are risks related to device implantation to deliver invasive VNS compared to non-invasive VNS (Korupolu et al., 2024). Future human comparison studies are required to study and quantify the efficacy vs. risks of paired VNS delivered via different methods with rehabilitation. Invasive VNS studies reported severe adverse events such as vocal cord palsy, dysphagia, surgical site infection, and hoarseness of voice, which were found to be related to surgery (Korupolu et al., 2024). 

NON-IMPLANTABLE TRANSCUTANEOUS VAGUS NERVE STIMULATION

The purpose of non-implantable tVNS is to noninvasively apply low-voltage electrical currents to stimulate the cervical branch of the vagus nerve. nVNS has been tested primarily in the setting of headache. nVNS has been proposed as an intervention to relieve pain in acute attacks of cluster or migraine headaches as an alternative to standard care and to reduce the frequency of attacks for both cluster headaches and migraine as an adjunct to standard care. Proposed uses have been tested in other neurologic, psychiatric, or metabolic disorders as well. tVNS is being investigated as a noninvasive alternative to surgery for numerous indications.
 
PROPHYLAXIS AND TREATMENT OF CLUSTER AND MIGRAINE HEADACHES
In an open-label, single-arm, pilot study, Goadsby et al. (2014) evaluated a novel nVNS for acute treatment of migraine. Participants with migraine (with or without aura) were eligible for this study. Up to four migraine attacks were treated with two 90-second doses, at 15-minute intervals delivered to the right cervical branch of the vagus nerve within a 6-week time period. Subjects were asked to self-treat at moderate or severe pain, or after 20 minutes of mild pain. Of 30 enrolled individuals (25 females, 5 males, median age of 39 years), two treated no attacks, and one treated aura only, leaving a full analysis set of 27 treating 80 attacks with pain. An adverse event was reported in 13 individuals, notably: neck twitching (n=1), raspy voice (n=1) and redness at the device site (n=1). No unanticipated, serious, or severe adverse events were reported. The pain-free rate at 2 hours was 4 of 19 (21%) for the first treated attack with a moderate or severe headache at baseline. For all moderate or severe attacks at baseline, the pain-free rate was 12/54 (22%). The authors concluded that nVNS may be an effective and well-tolerated acute treatment for migraine in certain individuals. These preliminary findings need to be validated by well-designed studies.

In 2015, Kinfe et al. enrolled 20 individuals  with treatment-refractory migraine in this 3-month, open-label, prospective, noncomparative observational study of preventive nVNS. The number of headache days per month decreased from 14.7 to 8.9 (P<0.01) between baseline and end of treatment (3 months). The migraine disability assessment score improved from 26 to 15 (P<0.01).

Nesbitt et al. (2015) reported their initial experience with a novel device, designed to provide portable, noninvasive, transcutaneous stimulation of the vagus nerve, both acutely and preventively, as a treatment for cluster headache. Individuals with cluster headache (11 chronic, eight episodic), from two centers, including seven who were refractory to drug treatment, had sufficient data available for analysis in this open-label observational cohort study. The device, known as the gammaCore, was used acutely to treat individual attacks as well as to provide prevention. Patient-estimated efficacy data were collected by systematic inquiry during follow-up appointments up to a period of 52 weeks of continuous use. Fifteen individuals reported an overall improvement in their condition, with four reporting no change, providing a mean overall estimated improvement of 48%. Of all attacks treated, 47% were aborted within an average of 11±1 minutes of commencing stimulation; 10 individuals reduced their acute use of high-flow oxygen by 55%, with nine reducing use of triptan by 48%. Prophylactic use of the device resulted in a substantial reduction in estimated mean attack frequency from 4.5/24 hours to 2.6/24 hours (P<0.0005) posttreatment. The authors concluded that these data suggested that noninvasive VNS may be practical and effective as an acute and preventive treatment in chronic cluster headaches. They stated that further evaluation of this treatment using randomized sham-controlled trials is thus warranted. This study provided Class IV evidence that for individuals with cluster headache, transcutaneous stimulation of the vagus nerve aborts acute attacks and reduces the frequency of attacks.

Puledda and Goadsby (2016) stated that neuromodulation is a promising, novel approach for the treatment of primary headache disorders. Neuromodulation offers a new dimension in the treatment that is both easily reversible and tends to be very well-tolerated. The autonomic nervous system is a logical target given the neurobiology of common primary headache disorders, such as migraine and the trigeminal autonomic cephalalgias (TACs). These investigators reviewed new encouraging results of studies from the most recent literature on neuromodulation as acute and preventive treatment in primary headache disorders, and discussed some possible underlying mechanisms. These researchers focused on vagal nerve stimulation (VNS) and sphenopalatine ganglion stimulation (SPGS) since they have targeted autonomic pathways that are cranial and can modulate relevant pathophysiological mechanisms. The initial data suggested that these approaches will find an important role in headache disorder management going forward. The authors concluded that the armamentarium for the treatment of migraine and the TACs is rapidly expanding thanks to neuromodulation techniques. The newer methods appear much better tolerated and offer important therapeutic benefits. Equally attractive in many ways is that bench-based understanding is being applied to neuromodulation to yield bedside advances in treatment. They stated that clinicians can look forward to the results of a number of ongoing studies and the real possibility to add these exciting methods to their practice.

In 2016, Silberstein et al. published the results from the EVENT trial, which was a feasibility study of prevention with a sample size of 59 individuals. It was not powered to detect differences in efficacy outcomes. For the outcome of response, defined as 50% or more reduction in the number of headache days, 10% of the individuals in the nVNS group versus 0% in the sham group were responders; statistical testing was not performed.

In a prospective, open-label, randomized study, Gaul et al. (2016) compared adjunctive prophylactic nVNS (n=48) with standard of care (SoC) alone (control; n=49) for the acute treatment of chronic cluster headache (cCH). A 2-week baseline phase was followed by a 4-week randomized phase (SoC plus nVNS vs control) and a 4-week extension phase (SoC plus nVNS). The primary endpoint was the reduction in the mean number of cluster headache (CH) attacks per week. Response rate, abortive medication use and safety/tolerability were also assessed. During the randomized phase, individuals in the intent-to-treat population treated with SoC plus nVNS (n=45) had a significantly greater reduction in the number of attacks per week versus controls (n=48) (−5.9 vs −2.1, respectively) for a mean therapeutic gain of 3.9 fewer attacks per week (95% CI, 0.5– 7.2; P=0.02). Higher (≥ 50%) response rates were also observed with SoC plus nVNS (40% [18/45]) versus controls (8.3% [4/48]; P<0.001). No serious treatment-related adverse events occurred. The authors concluded that adjunctive prophylactic nVNS is a well-tolerated novel treatment for chronic CH, offering clinical benefits beyond those with SoC.

The authors stated that study limitations included the lack of a placebo/sham device, an open-label study design, the short treatment duration and the use of patient-reported outcomes. No placebo arm was incorporated into the study because a suitable placebo/sham device had not yet been designed. Instead of a placebo/sham arm, SoC was deemed the most appropriate control treatment that was reflective of a real-world clinical scenario. The open-label study design and short treatment duration may have contributed to a placebo effect in both treatment groups. The 16.7% response rate in the control group during the extension phase may partially reflect a placebo response to nVNS. The initial response experienced in the control group during the randomized phase may have also impacted the capacity for a meaningful response to nVNS during the extension phase. Furthermore, fewer individuals in the control arm (50%) than in the nVNS arm (64.4%) were highly adherent (≥80%) to prophylactic nVNS, which may have further confounded response rates and reductions in abortive medication use in this group. Only individuals with chronic, treatment-refractory CH were included because of their stable CH attack frequency and intensity. A 2.5-month study duration was deemed sufficient to observe a treatment effect. Treatment response in favor of nVNS was consistent across intent-to-treat (ITT), modified ITT (mITT) and per-protocol populations (per-protocol population was defined as participants in the mITT population who had ≥ 12 days of observation in the randomized phase and no major protocol violation). Because no CH-specific QOL instruments exist, the EQ-5D-3L and HIT-6 measures were considered most appropriate, and nVNS prophylaxis resulted in meaningful improvements for both measures. The apparent lack of effect of acute nVNS therapy on CH duration or severity was consistent with findings in the chronic CH population that were reported in a recent study of acute nVNS therapy for CH. The nVNS adherence rates in this study (50%–64%) were consistent with those reported for prophylactic noninvasive neuromodulation in migraine and were considered meaningful given that twice-daily nVNS requires more effort and participation than a conventional oral medication regimen.

In a randomized, double-blind, sham-controlled study (ACT1), Silberstein et al. (2016) evaluated nVNS as an acute CH treatment. A total of 150 subjects were enrolled and randomly assigned (1:1) to receive nVNS or sham treatment for less than or equal to 1 month during a double-blind phase; completers could enter a 3-month nVNS open-label phase. The primary endpoint was response rate, defined as the proportion of subjects who achieved pain relief (pain intensity of 0 or 1) at 15 minutes after treatment initiation for the first CH attack without rescue medication use through 60 minutes; secondary endpoints included the sustained response rate (15–60 minutes). Subanalyses of eCH and cCH cohorts were pre-specified. The intent-to-treat population comprised 133 subjects: 60 nVNS-treated (eCH, n=38; cCH, n=22) and 73 sham-treated (eCH, n=47; cCH, n=26). A response was achieved in 26.7% of nVNS-treated subjects and 15.1% of sham-treated subjects (P=0.1). Response rates were significantly higher with nVNS than with sham for the eCH cohort (nVNS, 34.2%; sham, 10.6%; P=0.008) but not the cCH cohort (nVNS, 13.6%; sham, 23.1%; P=0.48). Sustained response rates were significantly higher with nVNS for the eCH cohort (P=0.008) and total population (P=0.04). Adverse device effects (ADEs) were reported by 35 of 150 (nVNS, 11; sham, 24) subjects in the double-blind phase and 18 of 128 subjects in the open-label phase. No serious ADEs occurred. The authors concluded that in one of the largest randomized sham-controlled studies for acute CH treatment, the response rate was not significantly different (versus sham) for the total population; nVNS provided significant, clinically meaningful, rapid, and sustained benefits for eCH but not for cCH, which affected results in the total population. They stated that this safe and well-tolerated treatment represents a novel and promising option for eCH.

The authors noted that the drawbacks of this study included the analysis of the cCH cohort as part of the primary endpoint, the need for careful interpretation of subanalyses results, challenges with blinding inherent in medical device studies, and the time to first measurement of response used to define the primary efficacy endpoint. Primary endpoint results were significant for the eCH cohort but were diminished overall by the cCH cohort results. When subanalyses results were interpreted, the lack of statistical powering and the potential for type 1 and type 2 errors (in the eCH and cCH cohorts, respectively) should be considered. The difference in AE descriptions provided by subjects treated with the nVNS (e.g., drooping/pulling of the lip/face) and sham (e.g., burning, soreness, stinging) devices may help to explain results of the blinding analyses, which were similar to those observed in previous sham-controlled trials. The burning sensation and other pain-related AEs reported by the sham-treated group in ACT1 may have led to a placebo effect based on impressions that the subjects were receiving active treatment. Sham device–associated pain may have also produced a diffuse noxious inhibitory control (DNIC) effect, a phenomenon in which the application of a noxious electrical stimulus to remote body regions inhibits dorsal horn activity and attenuates the original pain. Potential placebo and DNIC effects in the sham group may have reduced the magnitude of the therapeutic benefit associated with nVNS treatment. Another drawback was that the time-point used to define the ACT1 primary end-point was 15 minutes after treatment initiation, which has been used in other CH studies, rather than after treatment completion. In ACT1, this 15-minute interval comprised an 8‐minute nVNS stimulation period followed by only a 7-minute period that appeared to be sufficient for significant treatment effects to become evident in the eCH cohort but not in the cCH cohort or total population. The 15-minute assessment time-point may have also contributed to the nonsignificant difference in average pain intensities between the nVNS and sham groups; other potential contributing factors include the combined statistical influence of the responders and nonresponders as well as the assessment after all attacks (rather than after the first attack). Thus, methodological implications in ACT1 regarding distinct effects among the eCH and cCH cohorts, the painful sham stimulation, and the use of a longer time-point to first measurement of response such as 30 minutes, as used in CH studies of other therapies, should be considered for future RCTs.

In 2016, Grazzi et al. reported on the use of preventive nVNS in an open-label, prospective, noncomparative study of 56 women with menstrual migraine. The treatment period was 12 weeks. At the end of treatment, the mean number of headache days per month was reduced from baseline (7.2–4.7; P<0.01). Twenty individuals (39%; 95% CI, 26%–54%) had a greater than or equal to 50% reduction in headache days.

Lainez and Guillamon (2017) summarized CH pathophysiology and the effectiveness of various neuromodulating techniques. In individuals with cCH, VNS with a portable device used in conjunction with SoC in CH individuals resulted in a reduction in the number of attacks. The authors concluded that new recent noninvasive approaches such as nVNS have shown effectiveness in a few trials and could be an interesting alternative in the management of CH, but require more testing and positive RCTs.

An UpToDate review on “Cluster headache: Treatment and prognosis" (May 2017) states that “When chronic cluster headache is unresponsive to medical treatments, various surgical interventions and neurostimulation techniques are potential treatment options, though none are clearly established as effective. In such cases, it is particularly important to exclude potential causes of secondary cluster headache. Neurostimulation techniques, including sphenopalatine ganglion stimulation and VNS, appear promising but remain investigational. Destructive surgical procedures are unproven and should be viewed with great caution."

Yuan and Silberstein (2017) stated that neuromodulation is an emerging area in headache management. Through neurostimulation, multiple brain areas can be modulated to alleviate pain, hence reducing the pharmacological need. These investigators discussed the recent development of the VNS for headache management. Early case series from epilepsy and depression cohorts using invasive VNS showed a serendipitous reduction in headache frequency and/or severity. Noninvasive VNS, which stimulates the carotid vagus nerve with the use of a personal handheld device, also demonstrated efficacy for acute migraine or CH attacks. Long-term use of nVNS appeared to exert a prophylactic effect for both chronic migraine and cCH. In animal studies, nVNS modulated multiple pain pathways and even lessen cortical spreading depression. Progression in nVNS clinical efficacy over time suggests an underlying disease-modifying neuromodulation. The authors concluded that nVNS appears to be as effective as the invasive counterpart for many indications. They noted that with an enormous potential therapeutic gain and a high safety profile, further development and application of nVNS is promising.

Miller and Matharu (2017) noted that there is growing interest in neuromodulation for primary headache conditions. Invasive modalities such as orbital nerve stimulation (ONS), deep brain stimulation (DBS) and SPGS are reserved for the most severe and intractable individuals. Noninvasive options such as VNS, supraorbital nerve stimulation, and transcranial magnetic nerve stimulation (TMS) have all emerged as potentially useful headache treatments. These researchers examined the evidence base for noninvasive neuromodulation in TACs and migraine. Although a number of open-label series of noninvasive neuromodulation devices have been published, there is very little controlled evidence for their use in any headache condition. Open-label evidence suggested that VNS may have a role in the prophylactic treatment of CH and there is limited evidence to suggest it may be useful in the acute treatment of cluster and potentially migraine attacks. There is limited controlled evidence to suggest a role for SONS in the prophylactic treatment of episodic migraine; however, there is no evidence to support its use in CH. TMS may be effective in the acute treatment of episodic migraine; but there is no controlled evidence to support its use as a preventative in any headache condition. The authors concluded that noninvasive neuromodulation techniques are an attractive treatment option with excellent safety profiles; however, their use is not yet supported by high-quality RCTs.

Mwamburi et al. (2017a) noted that CH is a debilitating disease characterized by excruciatingly painful attacks that affects 0.15% to 0.4% of the US population. Episodic cluster headache manifests as circadian and circannual seasonal bouts of attacks, each lasting 15 to 180 minutes, with periods of remission. In cCH, the attacks occur throughout the year with no periods of remission. Although existing treatments are effective for some individuals, many individuals continue to suffer. There are only two FDA-approved medications for eCH in the United States; others, such as high-flow oxygen, are used off-label. Episodic CH is associated with co-morbidities and affects work, productivity, and daily functioning. The economic burden of eCH is considerable, costing more than twice that of nonheadache individuals. These researchers stated that gammaCore adjunct to SoC was found to have superior efficacy in treatment of acute eCH compared with sham-gammaCore used with SoC in ACT1 and ACT2 trials. However, the economic impact has not been characterized for this indication. These investigators conducted a cost-effectiveness analysis of gammaCore adjunct to SoC compared with SoC alone for the treatment of acute pain associated with eCH attacks. The model structure was based on treatment of acute attacks with three outcomes: (i) failures, (ii) nonresponders, and (iii) responders. The time horizon of the model is 1 year using a payer perspective with uncertainty incorporated. Parameter inputs were derived from primary data from the RCTs for gammaCore. The mean annual costs associated with the gammaCore-plus-SoC arm was $9510, and mean costs for the SoC-alone arm was $10,040. The mean quality-adjusted life years for gammaCore-plus-SoC arm were 0.83, and for the SoC-alone arm, they were 0.74. The gammaCore-plus-SoC arm was dominant over SoC alone. All one-way and multiway sensitivity analyses were cost-effective using a threshold of $20,000. The authors concluded that gammaCore dominance, representing savings, was driven by superior efficacy, improvement in QOL, and reduction in costs associated with successful and consistent abortion of episodic attacks. They stated that these findings serve as additional economic evidence to support coverage for gammaCore. Moreover, they stated that additional real-world data are needed to characterize the long-term impact of gammaCore on co-morbidities, utilization, QOL, daily functioning, productivity, and social engagement of these individuals, and for other indications.
 
Mwamburi et al. (2017b) stated that the FDA has cleared gammaCore (nVNS) for the treatment of eCH. With the exception of subcutaneous sumatriptan, all other treatments are used off-label and have many limitations. The FDA approval process for devices differs from that of drugs. These researchers performed a review of the literature to evaluate new evidence on various aspects of gammaCore treatment and impact. The ACute Treatment of Cluster Headache Studies (ACT1 and ACT2), both double-blind sham-controlled randomized trials, did not meet the primary end-points of the trials; but each demonstrated significant superiority of gammaCore among individuals with eCH. In ACT1, gammaCore resulted in a higher response rate (RR) (RR, 3.2; 95% CI, 1.6–8.2; P=0.014), higher pain-free rate for greater than 50% of attacks (RR, 2.3; 95% CI, 1.1–5.2; P=0.045), and shorter duration of attacks (MD, −30 minutes; P<0.01) compared with the sham group. In ACT2, gammaCore resulted in higher odds of achieving pain-free attacks in 15 minutes (OR, 9.8; 95% CI, 2.2–44.1; P=0.01), lower pain intensity in 15 minutes (MD, −1.1; P<0.01), and higher rate of achieving responder status at 15 minutes for greater than or equal to 50% of treated attacks (RR, 2.8; 95% CI, 1.0–8.1; P=0.058) compared with the sham group. The PREVention and Acute Treatment of Chronic Cluster Headache (PREVA) study also demonstrated that gammaCore plus SoC was superior to SoC alone in individuals with cCH. Medical costs, pharmacy refills, and pharmacy costs were higher in individuals coded for CH in claims data compared with controls with non-headache codes. These researchers stated that gammaCore is easy to use, practical, and safe; delivery cannot be wasted; and individuals prefer using gammaCore compared with SoC. The treatment improved symptoms and reduces the need for CH rescue medications. They stated that current US reimbursement policies, which predated nVNS and are based on expensive, surgically implanted, and permanent implanted VNS (iVNS), need to be modified to distinguish nVNS from iVNS. The authors concluded that there is sufficient evidence to support the need to modify current reimbursement policies to include coverage for gammaCore (nVNS) for eCH. Moreover, they stated that one drawback was that the information available from publications that contribute to a review was as reported. This review, however, added new information to the body of evidence, particularly in comparison with previous reviews. While authors of previous reviews had identified gammaCore as a beneficial intervention for individuals with CH, they also pointed to a gap and a need for clinical trials to provide further evidence on its safety and effectiveness. They stated that the recommended future path is to collect real-world data that are specific to individuals suffering from eCH and CH with regard to use or non-use of gammaCore via a registry to monitor usage and performance measurement. Additionally, stakeholders should periodically review data from claims databases to evaluate long-term outcomes related to symptoms, utilization, cost, and reimbursement burden and the impact on co-morbidities and all-cause healthcare utilization, to better understand the value associated with gammaCore use beyond symptom relief. Also needed are continued research efforts, using RCTs, to characterize the benefits of gammaCore in other indications, including migraine, specific inflammatory illnesses, cardiac diseases, and psychiatric disorders.

Silberstein et al. (2017) noted that a panel of nine experts, including neurologists, other headache specialists, and medical and pharmacy directors, from four health plans (one integrated delivery network and three plans with commercial, Medicare, and Medicaid lines of business), convened to discuss CH. Topics covered included the current treatment landscape, treatment challenges, economic impact of disease, and gaps in care for individuals with CH. One major challenge in the management of CH is that it is under-recognized and frequently misdiagnosed, leading to delays in and suboptimal treatment for individuals who suffer from this painful and disabling condition. The management of CH is challenging due to the lack of a robust evidence base for preventive treatment, the AEs associated with conventional preventive treatments, the variability of response to acute treatments, and the challenging reimbursement landscape for well-accepted treatments (e.g., oxygen). The lack of effective prevention for many individuals may lead to the excessive use of acute therapies, often multiple times each day, which drives the cost of illness up significantly. The goal of the panel discussion was to discuss the role of gammaCore, the recently released first nVNS therapy in the acute treatment of individuals with eCH, in the management of CH. The panel reviewed current practices and formulated recommendations on incorporating a newly released therapy into CH management. The panel explored the role of traditional management strategies as well as that of gammaCore in the acute treatment of individuals with eCH. The panel agreed that the treatment guidelines should be updated to reflect the role of gammaCore as a first-line, acute therapeutic option for individuals with eCH and that payers should offer coverage of gammaCore to their members who have a diagnosis of eCH. Healthcare providers, including headache specialists and neurologists, and payers are encouraged to remain up-to-date regarding the results of ongoing clinical trials evaluating the use of gammaCore for the acute and/or preventive treatment of migraine to ensure that individuals are being appropriately treated for these conditions and that they have access to treatment through their insurers. Moreover, the panel noted that additional studies need to be conducted in the United States to verify the role of gammaCore in the preventive therapy of eCH and cCH.

Simon and Blake (2017) noted that stimulation of the cervical vagus nerve with iVNS has been used clinically for more than 20 years to treat individuals with epilepsy. More recently, gammaCore, a nVNS, was developed, which has been purported to also stimulate the vagus nerve without the cost and morbidity associated with an iVNS system. The gammaCore device has been used to acutely treat various types of primary headaches, including migraine and CH, and for the prevention of episodic, chronic, and menstrual migraines and CH. The gammaCore device was cleared by the FDA for the acute treatment of pain in individuals with eCH. These investigators summarized the clinical work that has been published in the use of gammaCore for treating primary headache disorders, presented an overview of studies demonstrating that nVNS does indeed stimulate similar vagus nerve fibers as the implantable VNS system, and then presented several animal headache-related studies that address the mechanism of action (MOA) of nVNS. The authors concluded that preliminary clinical studies in various primary headache disorders are encouraging. Human studies and modeling have demonstrated that nVNS activates vagus nerve fibers similar to those implicated in the clinical benefits of iVNS. They stated that continuing human and animal research is needed to further elucidate the MOA and to help define optimal signal parameters and treatment paradigms for headache and other disorders.

Gaul et al. (2017) stated that although the PREVA trial did not examine the effects of nVNS in individuals with eCH, the rapid beneficial effects on attack frequency observed within 2 weeks of treatment initiation in this cCH analysis, combined with the established safety profile of nVNS, suggested that a trial in eCH would be clinically reasonable.

Ho et al. (2017) noted that SPG is the largest collection of neurons in the calvarium outside of the brain. During the past century, it has been a target for interventional treatment of head and facial pain due to its ease of access. Block, radiofrequency ablation (RFA), and neurostimulation have all been applied to treat a myriad of painful syndromes. Despite the routine use of these interventions, the literature supporting their use has not been systematically summarized. These investigators summarized the level of evidence supporting the use of SPG block, RFA, and neurostimulation. Medline, Google Scholar, and the Cochrane Central Register of Controlled Trials (CENTRAL) databases were reviewed for studies on SPG block, RFA, and neurostimulation. Studies included in this review were compiled and analyzed for their treated medical conditions, study design, outcomes and procedural details. Studies were graded using Oxford Center for Evidence-Based Medicine for level of evidence. Based on the level of evidence, grades of recommendations are provided for each intervention and its associated medical conditions. A total of 83 publications were included in this review, of which 60 were studies on SPG block, 15 were on RFA, and eight were on neuro-stimulation. Of all the studies, 23 had evidence level above case series. Of the 23 studies, 19 were on SPG block, one study on RFA, and three studies on neurostimulation. The rest of the available literature was case reports and case series. The strongest evidence lied in using SPG block, RFA, and neurostimulation for CH; SPG block also had evidence in treating trigeminal neuralgia, migraines, reducing the needs of analgesics after endoscopic sinus surgery and reducing pain associated with nasal packing removal after nasal operations. The authors concluded that SPG is a promising target for treating CH using blocks, RFA, and neurostimulation; SPG block also had some evidence supporting its use in a few other conditions. Moreover, they stated that most of the controlled studies were small and without replications; further controlled studies are needed to replicate and expand on these previous findings.

Goadsby et al. (2018) reported on the results of a randomized, double-blind, sham-controlled study (ACT2) for the treatment of acute cluster headache attacks. Ninety-two individuals with cluster headaches were randomly assigned to tVNS (described in this response as nVNS) or sham treatment. Individuals were further identified as having eCHs or cChs and randomly assigned at approximately 1:1 to the tVNS and sham treatment groups. The primary efficacy endpoint was the ability to achieve pain-free status within 15 minutes of initiation of treatment without use of rescue treatment. There was no difference between tVNS-treated and sham-treated individuals in the overall cluster headache study population. Subgroup analysis of the cCh population showed no differences between tVNS-treated and sham-treated individuals. For the episodic cluster headaches subgroup, tVNS demonstrated a 48% response rate compared with 6% response rate for sham-treated (P<0.01). The interaction P value for the subgroup analysis was statistically significant ( P=0.04).

An UpToDate review on “Cluster headache: Treatment and prognosis" (2018) states that “There are several promising but unproven methods using neurostimulation to treat medically refractory cluster headache, including sphenopalatine ganglion stimulation, occipital nerve stimulation, noninvasive VNS, and deep brain stimulation. All are investigational and require further study to confirm long-term benefit and safety."

Sanchez-Gomez et al. (2018) evaluated the safety and effectiveness of peripheral neurostimulation of the SPG in the treatment of refractory cCH. Various medical databases were used to perform a systematic review of the scientific literature. The search for articles continued until October 31, 2016, and included clinical trials, systematic reviews and/or meta-analyses, health technology assessment reports, and clinical practice guidelines that included measurements of efficiency/effectiveness or adverse effects associated with the treatment. The review excluded cohort studies, case-control studies, case series, literature reviews, letters to the editor, opinion pieces, editorials, and studies that had been duplicated or outdated by later publications from the same institution. Regarding effectiveness, these investigators found that SPG stimulation had positive results for pain relief, attack frequency, medication use, and individuals' QOL. In the results regarding safety, these researchers found a significant number of AEs in the first 30 days following the intervention. Removal of the device was necessary in some individuals. Little follow-up data, and no long-term data, were available. The authors concluded that these findings are promising, despite the limited evidence available. They considered it essential for research to continue into the safety and efficacy of SPG stimulation for individuals with refractory cCH. In cases where this intervention may be indicated, treatment should be closely monitored.

de Coo et al. (2019) combined the data from ACT1 and ACT2 meta-analytically for the two primary outcomes reported in the two studies. The authors reported an interaction between treatment group and CH subtype in the pooled analysis (P<0.05 for both outcomes).

In 2018, the results of a multicenter, double-blind, randomized, sham-controlled trial (the PRESTO trial) of acute treatment of migraine with nVNS in 248 individuals with episodic migraine with/without aura were reported in three separate publications (Tassorelli et al., 2018; Martelletti et al., 2018; Grazzi et al. , 2018). The primary efficacy outcome was the proportion of participants who were pain-free without using rescue medication at 120 minutes. There was not a statistically significant difference in the primary outcome (30% vs. 20%; P=0.07) although it favored the nVNS group. The nVNS group had a higher proportion of individuals with decrease in pain from moderate or severe to mild or no pain at 120 minutes (41% vs. 28%; P=0.03) and a higher proportion of individuals who were pain-free at 120 for 50% or more of their attacks (32% vs. 18%; P=0.02). PRESTO results did not include QOL or functional outcomes and the double-blind treatment and follow-up period was 4 weeks. In the additional 4 weeks of acute nVNS in the open-label period, rates of pain-free response after the first treated attack (28%) and pain relief (43.4%) were similar to the rates in the double-blind period.

In 2018, Trimboli et al. reported on the preventive and acute treatment of nVNS in 41 consecutive individuals with refractory primary chronic headaches (n=23 with chronic migraine) in an open-label, prospective, noncomparative clinical audit. Response was defined as at least 30% reduction in headache days/episodes after 3 months of treatment. Two of 23 (9%) individuals with chronic migraine met the definition for responder.

In 2019, Diener et al. published the results from a phase 3, multicenter, sham-controlled RCT (the PREMIUM trial) conducted in several European countries including individuals who experienced five to 12 migraine days per month. The study included a 4-week run-in period during which no treatment was administered; 477 participants entered the run-in. The criteria to remain eligible after run-in were not described in the publication. After run-in, 341 participants were randomly assigned (nVNS, n=169 or sham, n=172) to a 12-week double-blind treatment period followed by a 24-week open-label period of nVNS. Individuals administered two 120-second stimulations bilaterally to the neck with gammaCore, three times daily. nVNS was not statistically significantly superior to sham with respect to the outcomes of reduction of at least 50% in migraine days from baseline to the last 4 weeks, reduction in number of migraine days from baseline to the last 4 weeks or acute medication days in the intention-to-treat population.

In 2020, Lai et al. analyzed the effectiveness and safety of peripheral nerve stimulation of the cervical branch of the vagal nerve for primary headache disorders. A systematic review and meta-analysis of the literature was carried out on RCTs of nVNS for treating headaches. A random-effects model was used to report all outcomes. The primary outcomes were a reduction in headache days or attacks and pain-free status within 30 minutes. Secondary outcomes were the pain-relief status within 30 minutes, the pain-relief status at 60 minutes, abortive medication use, greater than or equal to 50% responder rate, pain-free status in greater than or equal to 50% of treated attacks, adverse events, and satisfaction. In total, 983 individuals were included from six trials. The authors found that nVNS was effective in achieving a pain-free status within 30 min (odds ratio [OR], 2.27; 95% confidence interval [CI], 1.16~4.44; P=0.02), pain-relief status within 30 min (OR, 1.8; 95% CI, 1.17~2.78; P=0.007), pain-relief status at 60 minutes (OR, 1.93; 95% CI, 1.2~3.1; P=0.006), a reduction in abortive medication use (OR, 0.61; 95% CI, 0.41~0.92; P=0.02), and pain-free status in greater than or equal to 50% of treated attacks (OR, 2.15; 95% CI, 1.27~3.66; P=0.005) compared to sham-device treatment. There were no significant differences in decreased headache days (standardized mean difference [SMD], −0.159; 95% CI, -0.357~0.04; P=0.117), adverse events (OR, 1.084; 95% CI, 0.559~2.104; P=0.811), or satisfaction (OR, 1.45; 95% CI, 0.97~2.17; P=0.07) between nVNS and sham-device treatment. The ≥50% responder rate could not be determined (OR, 3.34; 95% CI, 0.83~13.33; P=0.09; I 2=73%). The authors concluded that "cervical nVNS is effective for acute pain relief for migraine and cluster headache."

OTHER CONDITIONS
Epilepsy

The t-VNS system uses a noninvasive approach that combines a stimulation unit and ear electrode to stimulate the auricular branch of the vagus nerve (which supplies the skin over the concha of the ear) for the treatment of pharmacoresistant epilepsy. Individuals self-administer electric stimulation for several hours per day. Currently, the device does not have FDA approval.

In 2020, Wu et al. reported the results of a systematic review and meta-analysis of 3 RCTs (Aihua et al. 2014; Bauer et al. 2016; Rong et al. 2014) of tVNS for the treatment of drug-resistant epilepsy. All treatment groups underwent a cymba conchae stimulus at a frequency of 20 to 30 Hz. The control groups received various kinds of sham stimulation at a frequency of 1 Hz, the same frequency stimulation as treatment but at the nonauricular vagus nerve area or no stimulation. Meta-analysis of the RCTs found that seizure frequency was significantly reduced with tVNS (Mean Difference [MD]=−3.29; 95% CI, −6.31 to −0.27). However, meta-analysis of two RCTs that reported responder rates (undefined) did not find a significant difference between the tVNS and control groups (N=238; OR=0.47; 95% CI, 0.54−4.02]. All three RCTs assessed QOL using the Quality of Life in Epilepsy Inventory (QOLIE)-31 scale, but found no significant differences between treatment and control groups. Important limitations of the RCTs include imprecision, risk of confounding due to potentially imbalanced use of important nonprotocol interventions (i.e., concomitant antiepileptic drugs), and unacceptable flaws in outcome assessment (i.e., unspecified definition of response, between-group differences in measurement timing, lack of EEG data).
 
In 2016, Bauer et al. published the results of a randomized, double-blind controlled trial (cMPsE02) assessing the efficacy and safety of tVNS versus control stimulation in individuals with drug-resistant epilepsy. The primary objective was to demonstrate superiority of add-on therapy with tVNS (stimulation frequency 25 Hz, n=39) versus active control (1 Hz, n=37) in reducing seizure frequency over 20 weeks. Secondary objectives comprised reduction in seizure frequency from baseline to end of treatment, subgroup analyses and safety evaluation. Treatment adherence was 84% in the 1-Hz group and 88% in the 25-Hz group, respectively. Stimulation intensity significantly differed between the 1-Hz group (1.02 ± 0.83 mA) and the 25 Hz group (0.50 ± 0.47 mA; P=0.006). Mean seizure reduction per 28 days at end of treatment was −2.9% in the 1-Hz group and 23.4% in the 25-Hz group (P=0.146). In contrast to controls, there was a significant reduction in seizure frequency in individuals of the 25-Hz group who completed the full treatment period (20 weeks; n=26, 34.2%, P=0.034). Responder rates (25%, 50%) were similar in both groups. Subgroup analyses for seizure type and baseline seizure frequency revealed no significant differences. Adverse events were usually mild or moderate and comprised headache, ear pain, application site erythema, vertigo, fatigue, and nausea. Four serious adverse events were reported including one sudden unexplained death in individuals with epilepsy (SUDEP) in the 1-Hz group which was assessed as not treatment-related. The authors concluded that "tVNS had a high treatment adherence and was well tolerated. Superiority of 25 Hz tVNS over 1 Hz tVNS could not be proven in this relatively small study, which might be attributed to the higher stimulation intensity in the control group. Efficacy data revealed results that justify further trials with larger patient numbers and longer observation periods."

In 2014, Rong et al. evaluated the safety and effectiveness of transcutaneous auricular VNS (ta-VNS) for individuals with refractory epilepsy. A total of 144 individuals were randomly assigned to a ta-VNS group (n=98) or transcutaneous auricular non-VNS (tn-VNS) control group (n=46). Treatment was conducted twice per day for 24 weeks. After 8, 16, and 24 weeks of treatment, the individuals were evaluated according to the Modified Engel Scale (four classes). After 8 weeks, according to the medical ethic design, individuals in tn-VNS group were switched into ta-VNS group uniquely. After 8 weeks' treatment, 41.0% and 27.5% of individuals from ta-VNS and tn-VNS groups, respectively, experienced reduction in seizure frequency that reached I, II, and III levels according to the standards of the Modified Engel Scale compared with the baselines, indicating significant difference in seizure reduction between the two groups. After 24 weeks of treatment, individuals with ta-VNS had a 47.7% reduction, and tn-VNS, with an additional 16 weeks of treatment, reached 47.5% in reduction. After 8 weeks' treatment, the percentages of average seizure frequency in ta-VNS and tn-VNS were reduced by 42.6% and 11.5%, respectively, providing a statistically significant difference in the results between the two groups ( P<0.05). In addition, there were significant improvements in EEG and the quality of daily life of the individuals after treatment. The authors concluded that the "results show that this ta-VNS treatment can effectively reduce the frequency of seizures and improve the individual's QOL. This may be an effective treatment for refractory epilepsy. At the same time, it is also safe, economic, and widely applicable."

In 2014, Aihua et al. reported on results from a series of 60 individuals with pharmaco-resistant epilepsy treated with a tVNS device, who were randomized to stimulation over the earlobe (control group) or the Ramsay-Hunt zone (treatment group), which includes the external auditory canal and the conchal cavity and is considered to be the somatic sensory territory of the vagus nerve. Thirty individuals were randomized to each group; 4 subjects from the treatment group were excluded from analysis due to loss to follow-up (n=3) or adverse events (n=1), while 9 subjects from the control group were excluded from analysis due to loss to follow-up (n=2) or increase or lack of decrease in seizures or other reasons (n=7). In the treatment group, compared with baseline, the median monthly seizure frequency was significantly reduced after 6 months (5.5 months vs. 6.0 months; p<0.001) and 12 months (4.0 months vs. 6.0 months; p<0.001) of tVNS therapy. At 12-month follow-up, tVNS group subjects had a significantly lower median monthly seizure frequency compared with the control group (4.0 months vs. 8.0 months; p<0.001).
 
Two small case series identified used a tVNS device for treatment of medication-refractory seizures. In a small case series of 10 individuals with treatment-resistant epilepsy, Stefan et al. (2012) reported that three individuals withdrew from the study, while 5 of 7 individuals reported a reduction in seizure frequency. In another small case series, He et al. (2013) reported that among 14 pediatric individuals with intractable epilepsy who were treated with bilateral tVNS, of the 13 individuals who completed follow-up, the mean reduction in self-reported seizure frequency was 31.8% after 8 weeks, 54.1% from week 9 to 16, and 54.2% from week 17 to 24.

Fibromyalgia

In 2020, Kutlu et al. reported the results of an RCT that compared a home-based exercise treatment program with or without auricular VNS in 60 female individuals in Turkey with fibromyalgia syndrome (auricular VNS n=30 and no auricular VNS n=30). The VNS was delivered in 30-minute sessions on weekdays for 4 weeks. The home-based exercise program consisted of strengthening, stretching, isometric, and posture exercises that targeted the body and upper and lower extremities. When added to exercise, auricular VNS did not significantly improve mean scores on the Fibromyalgia Impact Questionnaire (37.27 vs. 41.93; P=0.378) or on any 36-Item Short Form Health Survey subscales (e.g., Physical Function: 80.00 vs. 85.00; P=0.167). An important limitation of this RCT is the lack of a sham control group.

Impaired Glucose Tolerance

In 2014, Huang et al. (2014) reported on results of a pilot RCT of a tVNS device that provides stimulation to the auricle for the treatment of impaired glucose tolerance. The trial included 70 individuals with impaired glucose tolerance who were randomized to active or sham tVNS, along with 30 controls who received no tVNS treatment. After 12 weeks of treatment, individuals who received active tVNS were reported to have significantly lower 2-hour glucose tolerance test results than those who received sham tVNS (7.5 mmol/L vs. 8 mmol/L; P=0.004).

Psychiatric Disorders

In 2013, Hein et al. reported on results of 2 pilot RCTs of a tVNS device for the treatment of depression, 1 of which included 22 subjects and another assessed 15 subjects. In the first study, 11 subjects were randomized to active or sham tVNS. At 2-week follow-up, Beck Depression Inventory (BDI) self-rating scores in the active stimulation group decreased from 27.0 to 14.0 points (p<0.001), while the sham-stimulated individuals did not show significant reductions in BDI scores (31.0 to 25.8 points). In the second study, 7 individuals were randomized to active tVNS, and eight individuals were randomized to sham tVNS. In this study, BDI self-rating scores in the active stimulation group decreased from 29.4 to 17.4 points (p<0.05) after 2 weeks, while the sham-stimulated individuals did not show a significant change in BDI scores (28.6 to 25.4 points). The authors did not report direct comparisons in BDI change scores between the sham- and active-stimulation groups.

In 2014, Shiozawa et al. conducted a systematic review of studies evaluating the evidence related to transcutaneous stimulation of the trigeminal or vagus nerve for psychiatric disorders. Overall, the studies assessed were limited by small size and poor generalizability.
 
In 2015, Hasan et al. reported on a randomized trial of tVNS for the treatment of schizophrenia. Twenty individuals were assigned to active tVNS or sham treatment for 12 weeks. There was no statistically significant difference in the improvement of schizophrenia status during the observation period.

Upper-Limb Impairment Due To Stroke

In 2020, Wu et al. reported the results of a randomized, pilot sham-controlled RCT in 21 individuals (nVNS=10 and sham nVNS, n=11) with upper limb motor function impairment following subacute ischemic stroke. The mean Fugl-Meyer assessment–upper extremity scores increased by 6.90 with nVNS versus 3.18 points with sham after 15 days of intervention (Difference= −3.72 points; 95% CI, −5.12 to -2.32; p≤.001). The improvement in the mean Fugl-Meyer assessment–upper extremity scores remained significantly higher at both the 4-week (+7.70 vs. +3.36; p≤.001) and the 12-week (+7.40 vs. +4.18; p=.038) follow-ups. There was only one adverse event noted, which was that one individual in the nVNS group developed skin redness at an electrode point of contact.

SOCIETY GUIDELINES AND POSITION STATEMENTS

AMERICAN ACADEMY OF NEUROLOGY
In 1999, the American Academy of Neurology released a consensus statement on the use of VNS in adults, which stated: “VNS is indicated for adults and adolescents over 12 years of age with medically intractable partial seizures who are not candidates for potentially curative surgical resections, such as lesionectomies or mesial temporal lobectomies." The Academy updated these guidelines in 2013, stating: “VNS may be considered for seizures in children, for LGS [Lennox-Gastaut syndrome]-associated seizures, and for improving mood in adults with epilepsy (Level C). VNS may be considered to have improved efficacy over time (Level C)."

AMERICAN PSYCHIATRIC ASSOCIATION
Updated in 2010, the American Psychiatric Association guidelines for the treatment of major depressive disorder in adults included the following statement on the use of VNS: “Vagus nerve stimulation (VNS) may be an additional option for individuals who have not responded to at least four adequate trials of antidepressant treatment, including ECT [electroconvulsive therapy]," with a level of evidence III (may be recommended on the basis of individual circumstances).

NATIONAL INSTITUTE FOR HEALTH AND CARE EXCELLENCE
National Institute for Health and Care Excellence (NICE) interventional procedures guidance on “Transcutaneous stimulation of the cervical branch of the vagus nerve for cluster headache and migraine" (2016) stated that “Current evidence on the safety of transcutaneous stimulation of the cervical branch of the vagus nerve for cluster headache and migraine raises no major concerns. The evidence on efficacy is limited in quantity and quality. Therefore, this procedure should only be used with special arrangements for clinical governance, consent and audit or research … Clinicians wishing to do transcutaneous stimulation of the cervical branch of the vagus nerve for cluster headache and migraine should ensure that individuals understand the uncertainty about the procedure's efficacy and provide them with clear written information … NICE encourages further research on transcutaneous stimulation of the cervical branch of the vagus nerve for cluster headache and migraine. Studies should describe whether the procedure is used for treatment or prevention, and whether it is used for cluster headache or migraine. Clinicians should clearly document details of patient selection and the treatment regimen. Outcome measures should include changes in the number and severity of cluster headache or migraine episodes, medication use, QOL in the short and long term, side effects, acceptability, and device durability".

The NICE published in 2018 a Medtech innovation briefing on nVNS for cluster headache (MIB162). The briefing states that the "intended place in therapy would be as well as standard care, most likely where standard treatments for cluster headache are ineffective, not tolerated or contraindicated" and that key uncertainties around the evidence are that "people with episodic and chronic cluster headaches respond differently to treatment with gammaCore. The optimal use of gammaCore in the different populations is unclear." In 2019, the National Institute for Health and Care Excellence published a Medical Technologies Guidance [MTG46] on gammaCore for cluster headache in December 2019. The recommendations state that evidence supports using gammaCore to treat cluster headache and that gammaCore is not effective in everyone with cluster headache.

The NICE published in 2020 an Interventional Procedure Overview on implanted VNS for TRD (IPG679). The guidance states: "Evidence on the safety of implanted vagus nerve stimulation for TRD raises no major safety concerns, but there are frequent, well-recognized side effects. Evidence on its efficacy is limited in quality. Therefore, this procedure should only be used with special arrangements for clinical governance, consent, and audit or research." The guidance further states that "NICE encourages further research into implanted vagus nerve stimulation for TRD, in the form of randomized controlled trials with a placebo or sham stimulation arm. Studies should report details of patient selection. Outcomes should include validated depression rating scales, patient-reported QOL, time to onset of effect and duration of effect, and any changes in concurrent treatment."

References

Aaronson ST, Carpenter LL, Conway CR, et al. Vagus nerve stimulation therapy randomized to different amounts of electrical charge for treatment-resistant depression: acute and chronic effects. Brain Stimul. 2013;6(4):631-640.

​Aaronson ST, Sears P, Ruvuna F, et al. A 5-Year Observational Study of Patients With Treatment-Resistant Depression Treated With Vagus Nerve Stimulation or Treatment as Usual: Comparison of Response, Remission, and Suicidality. Am J Psychiatry. 2017;174(7):640-648.

Aihua L, Lu S, Liping L, et al. A controlled trial of transcutaneous vagus nerve stimulation for the treatment of pharmacoresistant epilepsy. Epilepsy Behav. 2014;39:105-110.

Amar AP, Heck CN, Levy ML, et al. An institutional experience with cervical vagus nerve trunk stimulation for medically refractory epilepsy: rationale, technique, and outcome. Neurosurgery. 1998;43(6):1265-1276; discussion 1276-1280.

American Psychiatric Association, Work Group on Major Depressive Disorder, Gelenberg Aj, et al. Practice Guideline for the Treatment of Patients with Major Depressive Disorder. Third Edition. 2010; 3rd ed. Available at: http://psychiatryonline.org/pb/assets/raw/sitewide/practice_guidelines/guidelines/mdd.pdf. Accessed July 24, 2026.

Apovian CM, Shah SN, Wolfe BM, et al. Two-year outcomes of vagal nerve blocking (vBloc) for the treatment of obesity in the ReCharge Trial. Obes Surg. 2017;27(1):169-176.

Ardesch JJ, Buschman HP, Wagener-Schimmel LJ, et al. Vagus nerve stimulation for medically refractory epilepsy: a long-term follow-up study. Seizure. 2007;16(7):579-585.

Arhan E, Serdaroglu A, Kurt G, et al. The efficacy of vagal nerve stimulation in children with pharmacoresistant epilepsy: practical experience at a Turkish tertiary referral center. Eur J Paediatr Neurol. 2010;14(4):334-9. 

Arthur TM, Saneto RP, de Menezes MS, et al. Vagus nerve stimulation in children with mitochondrial electron transport chain deficiencies. Mitochondrion. 2007;7(4):279-83.​

Bajbouj M, Merkl A, Schlaepfer TE, et al. Two-year outcome of vagus nerve stimulation in treatment-resistant depression. J Clin Psychopharmacol. 2010;30(3):273-281.

Bauer S, Baier H, Baumgartner C, et al. Transcutaneous Vagus Nerve Stimulation (tVNS) for Treatment of Drug-Resistant Epilepsy: A Randomized, Double-Blind Clinical Trial (cMPsE02). Brain Stimul. 2016;9(3):356-363.

Ben-Menachem E, Hellstrom K, Waldton C, et al. Evaluation of refractory epilepsy treated with vagus nerve stimulation for up to 5 years. Neurology. 1999;52(6):1265-1267.

Ben-Menachem E, Manon-Espaillat R, Ristanovic R, et al. Vagus nerve stimulation for treatment of partial seizures: 1. A controlled study of effect on seizures. First International Vagus Nerve Stimulation Study Group. Epilepsia. 1994;35(3):616-626.

Bergfeld IO, Mantione M, Figee M, et al. Treatment-resistant depression and suicidality. J Affect Disord. 2018;235:362-367.

Berry SM, Broglio K, Bunker M, et al. A patient-level meta-analysis of studies evaluating vagus nerve stimulation therapy for treatment-resistant depression. Med Devices (Auckl). 2013;6:17-35.

Blue Cross and Blue Shield Association Technology Evaluation Center (TEC). Chronic vagus nerve stimulation for treatment of seizures. TEC Assessments. 1998;Volume 13:Tab 9.

Blue Cross and Blue Shield Association Technology Evaluation Center (TEC). Vagus nerve stimulation for treatment-resistant depression. TEC Assessments. 2005;Volume 21:Tab 7.

Blue Cross and Blue Shield Association Technology Evaluation Center (TEC). Vagus nerve stimulation for treatment-resistant depression. TEC Assessments. 2006;Volume 21:Tab 7.

Bottomley JM, LeReun C, Diamantopoulos A, et al. Vagus nerve stimulation (VNS) therapy in patients with treatment resistant depression: A systematic review and meta-analysis. Compr Psychiatry. 2019;98:152156.​

Cecchini AP, Mea E, Tullo V, et al. Vagus nerve stimulation in drug-resistant daily chronic migraine with depression: preliminary data. Neurol Sci. 2009;30(Suppl 1):S101-104.

Centers for Medicare & Medicaid Services (CMS). Coverage with Evidence Development. Vagus Nerve Stimulation (VNS) for Treatment Resistant Depression (TRD). 2019. Available at: https://www.cms.gov/Medicare/Coverage/Coverage-with-Evidence-Development/VNS. Accessed July 24, 2026.

Centers for Medicare & Medicaid Services (CMS). Decision Memo for Vagus Nerve Stimulation (VNS) for Treatment Resistant Depression (TRD) (CAG-00313R2). February 2019. Available at: https://www.cms.gov/medicare-coverage-database/details/nca-decision-memo.aspx?NCAId=292&NCDId=230&ncdver=3&IsPopup=y&bc=AAAAAAAACAAA&. Accessed July 24, 2026.

Centers for Medicare & Medicaid Services (CMS). National Coverage Determination (NCD) for Vagus Nerve Stimulation (VNS) (160.18). February 2019. Available at: https://www.cms.gov/medicare-coverage-database/details/ncd-details.aspx?NCDId=230&ncdver=3&NCSelection=NCD&DocID=160.18&kq=true&bc=IAAAAAgAAAAA&​. Accessed July 24, 2026.

Chavel SM, Westerveld M, Spencer S. Long-term outcome of vagus nerve stimulation for refractory partial epilepsy. Epilepsy Behav. 2003;4(3):302-309.

Cimpianu CL, Strube W, Falkai P, et al. Vagus nerve stimulation in psychiatry: a systematic review of the available evidence. J Neural Transm (Vienna). 2017;124(1):145-158.

Connor DE Jr, Nixon M, Nanda A, et al. Vagal nerve stimulation for the treatment of medically refractory epilepsy: a review of the current literature. Neurosurg Focus. 2012;32(3):E12. ​

Conway CR, Olin B, Aaronson ST, et al. A prospective, multi-center randomized, controlled, blinded trial of vagus nerve stimulation for difficult to treat depression: A novel design for a novel treatment. Contemp Clin Trials. 2020;95:​106066.​

Cristancho P, Cristancho MA, Baltuch GH, et al. Effectiveness and safety of vagus nerve stimulation for severe treatment-resistant major depression in clinical practice after FDA approval: outcomes at 1 year. J Clin Psychiatry. 2011;72(10):1376-1382.

Cukiert A, Cukiert CM, Burattini JA, et al. A prospective long-term study on the outcome after vagus nerve stimulation at maximally tolerated current intensity in a cohort of children with refractory secondary generalized epilepsy. Neuromodulation. 2013;16(6):551-556.

Curry SJ, Krist AH, Owens DK et al. Behavioral Weight Loss Interventions to Prevent Obesity-Related Morbidity and Mortality in Adults: US Preventive Services Task Force Recommendation Statement. JAMA. 2018;320(11):1163-1171.

Daban C, Martinez-Aran A, Cruz N, et al. Safety and efficacy of Vagus Nerve Stimulation in treatment-resistant depression. A systematic review. J Affect Disord. 2008;110(1-2):1-15.

Dawson J, Engineer ND, Prudente CN, et al. Vagus nerve stimulation paired with upper-limb rehabilitation after stroke: One-year follow-up. Neurorehabil Neural Repair. 2020;34(7):609-615.

Dawson J, Liu CY, Francisco GE, et al. Vagus nerve stimulation paired with rehabilitation for upper limb motor function after ischaemic stroke (VNS-REHAB): a randomised, blinded, pivotal, device trial. Lancet. 2021;397(10284):1545-1553.

Dawson J, Pierce D, Dixit A, et al. Safety, feasibility, and efficacy of vagus nerve stimulation paired with upper- limb rehabilitation after ischemic stroke. Stroke. 2016;47(1):143-150.

de Coo IF, Marin JC, Silberstein SD, et al. Differential efficacy of non-invasive vagus nerve stimulation for the acute treatment of episodic and chronic cluster headache: A meta-analysis. Cephalalgia. 2019;39(8):967-977.

De Ferrari GM, Crijns HJ, Borggrefe M, et al. Chronic vagus nerve stimulation: a new and promising therapeutic approach for chronic heart failure. Eur Heart J. 2011;32(7):847-855.

De Ridder D, Vanneste S, Engineer ND, et al. Safety and efficacy of vagus nerve stimulation paired with tones for the treatment of tinnitus: a case series. Neuromodulation. 2014;17(2):170-179.

DeGiorgio C, Heck C, Bunch S, et al. Vagus nerve stimulation for epilepsy: randomized comparison of three stimulation paradigms. Neurology. 2005;65(2):317-319.

DeGiorgio CM, Schachter SC, Handforth A, et al. Prospective long-term study of vagus nerve stimulation for the treatment of refractory seizures. Epilepsia. 2000;41(9):1195-1200.

Dibue-Adjei, M, Fischer, I, Steiger, HJ, and Kamp, MA. Efficacy of adjunctive vagus nerve stimulation in patients with Dravet syndrome: A meta-analysis of 68 patients. Seizure. 2017;50:147-152.

Dickie DA, Kimberley TJ, Pierce D, et al. An exploratory study of predictors of response to vagus nerve stimulation paired with upper-limb rehabilitation after ischemic stroke. Sci Rep. 2019;9(1):15902.​

Diener HC, Goadsby PJ, Ashina M, et al. Non-invasive vagus nerve stimulation (nVNS) for the preventive treatment of episodic migraine: The multicentre, double-blind, randomised, sham-controlled PREMIUM trial. Cephalalgia. 2019;39(12):1475-1487.

El TR, De HV, Raedt R, et al. Evolution in VNS therapy for refractory epilepsy, experience with Demipulse devices at Ghent University Hospital. Seizure. 2010;19(9):531-535.

Elger G, Hoppe C, Falkai P, et al. Vagus nerve stimulation is associated with mood improvements in epilepsy patients. Epilepsy Res. 2000;42(2-3):203-210.

Elliott RE, Rodgers SD, Bassani L, et al. Vagus nerve stimulation for children with treatment-resistant epilepsy: a consecutive series of 141 cases. J Neurosurg Pediatr. 2011;7(5):491-500.

Engineer CT, Hays SA, Kilgard MP. Vagus nerve stimulation as a potential adjuvant to behavioral therapy for autism and other neurodevelopmental disorders. J Neurodev Disord. 2017;9:20.

Englot DJ, Chang EF, Auguste KI. Vagus nerve stimulation for epilepsy: a meta-analysis of efficacy and predictors of response. J Neurosurg. 2011;115(6):1248-1255.

Englot DJ, Rolston JD, Wright CW, et al. Rates and predictors of seizure freedom with vagus nerve stimulation for intractable epilepsy. Neurosurgery. 2016;79(3):345-353.

Fisher, RS, Eggleston, KS, and Wright, CW. Vagus nerve stimulation magnet activation for seizures: A critical review. Acta Neurologica Scandinavica. 2014.

Fisher RS, Handforth A. Reassessment: vagus nerve stimulation for epilepsy: a report of the Therapeutics and Technology Assessment Subcommittee of the American Academy of Neurology. Neurology. 1999;53(4):666-669.

Frost M, Gates J, Helmers SL, et al. Vagus nerve stimulation in children with refractory seizures associated with Lennox-Gastaut syndrome. Epilepsia. 2001;42(9):1148-1152.

Garcia-Navarrete E, Torres CV, Gallego I, et al. Long-term results of vagal nerve stimulation for adults with medication-resistant epilepsy who have been on unchanged antiepileptic medication. Seizure. 2013;22(1):9-13.

Gaul C, Diener HC, Silver N, et al. Non-invasive vagus nerve stimulation for PREVention and Acute treatment of chronic cluster headache (PREVA): A randomised controlled study. Cephalalgia. 2016;36(6):534-546.

Gaul C, Magis D, Liebler E, Straube A. Effects of non-invasive vagus nerve stimulation on attack frequency over time and expanded response rates in patients with chronic cluster headache: A post hoc analysis of the randomised, controlled PREVA study. J Headache Pain. 2017;18(1):22.

Gaynes BN, Asher G, Gartlehner G, et al. Definition of Treatment-Resistant Depression in the Medicare Population [Internet]. Rockville (MD): Agency for Healthcare Research and Quality (US); 2018 Feb 9. PMID:30260611.

George MS, Rush AJ, Marangell LB, et al. A one-year comparison of vagus nerve stimulation with treatment as usual for treatment-resistant depression. Biol Psychiatry. 2005;58(5):364-373.

Goadsby PJ, de Coo IF, Silver N, et al. Non-invasive vagus nerve stimulation for the acute treatment of episodic and chronic cluster headache: A randomized, double-blind, sham-controlled ACT2 study. Cephalalgia. 2018;38(5):959-969.

Goadsby PJ, de Coo IF, Silver N, et al. Non-invasive vagus nerve stimulation for the acute treatment of episodic and chronic cluster headache: Findings from the randomized, double-blind, sham-controlled ACT2 study. Headache. 2017;57 Supplement 3128.

Goadsby PJ, Grosberg BM, Mauskop A, et al. Effect of noninvasive vagus nerve stimulation on acute migraine: an open-label pilot study. Cephalalgia. 2014;34(12):986-993.

Grazzi L, Egeo G, Calhoun AH, et al. Non-invasive Vagus Nerve Stimulation (nVNS) as mini-prophylaxis for menstrual/menstrually related migraine: an open-label study. J Headache Pain. 2016;17(1):91.

Grazzi L, Tassorelli C, de Tommaso M, et al. Practical and clinical utility of non-invasive vagus nerve stimulation (nVNS) for the acute treatment of migraine: a post hoc analysis of the randomized, sham-controlled, double-blind PRESTO trial. J Headache Pain. 2018;19(1):98.

Handforth A, DeGiorgio CM, Schachter SC, et al. Vagus nerve stimulation therapy for partial-onset seizures: a randomized active-control trial. Neurology. 1998;51(1):48-55.

Handforth A, Ondo WG, Tatter S, et al. Vagus nerve stimulation for essential tremor: a pilot efficacy and safety trial. Neurology. 2003;61(10):1401-1405.

Hasan A, Wolff-Menzler C, Pfeiffer S, et al. Transcutaneous noninvasive vagus nerve stimulation (tVNS) in the treatment of schizophrenia: a bicentric randomized controlled pilot study. Eur Arch Psychiatry Clin Neurosci. 2015;265(7):589-600.

He W, Jing X, Wang X, et al. Transcutaneous auricular vagus nerve stimulation as a complementary therapy for pediatric epilepsy: a pilot trial. Epilepsy Behav. 2013;28(3):343-346.

Healy S, Lang J, Te Water Naude J, et al. Vagal nerve stimulation in children under 12 years old with medically intractable epilepsy. Childs Nerv Syst. 2013;29(11):2095-2099.

Hein E, Nowak M, Kiess O, et al. Auricular transcutaneous electrical nerve stimulation in depressed patients: a randomized controlled pilot study. J Neural Transm. 2013;120(5):821-827.

Helmers SL, Duh MS, Guérin A, et al. Clinical outcomes, quality of life, and costs associated with implantation of vagus nerve stimulation therapy in pediatric patients with drug-resistant epilepsy. Eur J Paediatr Neurol. 2012;16(5):449-58.

Ho KWD, Przkora R, Kumar S. Sphenopalatine ganglion: Block, radiofrequency ablation and neurostimulation - a systematic review. J Headache Pain. 2017;18(1):118.

Hornig GW, Murphy JV, Schallert G, et al. Left vagus nerve stimulation in children with refractory epilepsy: an update. South Med J. 1997;90(5):484-488.

Huang F, Dong J, Kong J, et al. Effect of transcutaneous auricular vagus nerve stimulation on impaired glucose tolerance: a pilot randomized study. BMC Complement Altern Med. 2014;14:203.

Huf RL, Mamelak A, Kneedy-Cayem K. Vagus nerve stimulation therapy: 2-year prospective open-label study of 40 subjects with refractory epilepsy and low IQ who are living in long-term care facilities. Epilepsy Behav. 2005;6(3):417-423.

Ikramuddin S, Blackstone RP, Brancatisano A, et al. Effect of reversible intermittent intra-abdominal vagal nerve blockade on morbid obesity: the ReCharge randomized clinical trial. JAMA. 2014;312(9):915-922.

International Headache Society. International Classification of Headache Disorders 3rd Edition. 2018. Available at: https://www.ichd-3.org. Accessed July 24, 2026.

Kang HC, Hwang YS, Kim DS, et al. Vagus nerve stimulation in pediatric intractable epilepsy: a Korean bicentric study. Acta Neurochir Suppl. 2006;99:93-96.

Kimberley TJ, Pierce D, Prudente CN, et al. Vagus Nerve Stimulation Paired With Upper Limb Rehabilitation After Chronic Stroke. Stroke. 2018;49(11):2789-2792.

Kinfe TM, Pintea B, Muhammad S et al. Cervical non-invasive vagus nerve stimulation (nVNS) for preventive and acute treatment of episodic and chronic migraine and migraine-associated sleep disturbance: a prospective observational cohort study. J Headache Pain. 2015;16:101.

Klinkenberg S, Aalbers MW, Vles JS, et al. Vagus nerve stimulation in children with intractable epilepsy: a randomized controlled trial. Dev Med Child Neurol. 2012;54(9):855-861.

Klinkenberg S, van den Borne CJH, Aalbers MW, et al. The effects of vagus nerve stimulation on tryptophan metabolites in children with intractable epilepsy. Epilepsy and Behavior. 2014;37133-138.

Kutlu N, Ozden AV, Alptekin HK, et al. The Impact of Auricular Vagus Nerve Stimulation on Pain and Life Quality in Patients with Fibromyalgia Syndrome. Biomed Res Int. 2020;2020:8656218.

Labar D, Murphy J, Tecoma E. Vagus nerve stimulation for medication-resistant generalized epilepsy. E04 VNS Study Group. Neurology. 1999;52(7):1510-1512.

Lai YH, Huang YC, Huang LT, et al. Cervical noninvasive vagus nerve stimulation for migraine and cluster headache: a systematic review and meta-analysis. Neuromodulation. 2020;23(6):721-731.

Lainez MJ, Guillamon E. Cluster headache and other TACs: Pathophysiology and neurostimulation options. Headache. 2017;57(2):327-335.

Lange G, Janal MN, Maniker A, et al. Safety and efficacy of vagus nerve stimulation in fibromyalgia: a phase I/II proof of concept trial. Pain Med. 2011;12(9):1406-1413.

Liu AY, Rajji TK, Blumberger DM, et al. Brain stimulation in the treatment of late-life severe mental illness other than unipolar nonpsychotic depression. Am J Geriatr Psychiatry. 2014;22(3):216-240.

Majkowska-Zwolińska B, Zwoliński P, Roszkowski M, et al. Long-term results of vagus nerve stimulation in children and adolescents with drug-resistant epilepsy. Childs Nerv Syst. 2012;28(4):621-8.

Majoie HJ, Berfelo MW, Aldenkamp AP, et al. Vagus nerve stimulation in children with therapy-resistant epilepsy diagnosed as Lennox-Gastaut syndrome: clinical results, neuropsychological effects, and cost-effectiveness. J Clin Neurophysiol. 2001;18(5):419-428.

Majoie HJ, Berfelo MW, Aldenkamp AP, et al. Vagus nerve stimulation in patients with catastrophic childhood epilepsy, a 2-year follow-up study. Seizure. 2005;14(1):10-18.

Maleknia P, McWilliams TD, Barkley A, et al. Postoperative seizure freedom after vagus nerve stimulator placement in children 6 years of age and younger. J Neurosurg Pediatr. 2023;31(4):329-332.

Marangell LB, Rush AJ, George MS, et al. Vagus nerve stimulation (VNS) for major depressive episodes: one year outcomes. Biol Psychiatry. 2002;51(4):280-287.

Marangell LB, Suppes T, Zboyan HA, et al. A 1-year pilot study of vagus nerve stimulation in treatment-resistant rapid-cycling bipolar disorder. J Clin Psychiatry. 2008;69(2):183-189.

Martelletti P, Jensen RH, Antal A, et al. Neuromodulation of chronic headaches: position statement from the European Headache Federation. J Headache Pain. 2013;14(1):86.

Martelletti P, Barbanti P, Grazzi L, et al. Consistent effects of non-invasive vagus nerve stimulation (nVNS) for the acute treatment of migraine: additional findings from the randomized, sham-controlled, double-blind PRESTO trial. J Headache Pain. 2018;19(1):101.

Martin JL, Martin-Sanchez E. Systematic review and meta-analysis of vagus nerve stimulation in the treatment of depression: variable results based on study designs. Eur Psychiatry. 2012;27(3):147-155.

Mauskop A. Vagus nerve stimulation relieves chronic refractory migraine and cluster headaches. Cephalalgia. 2005;25(2):82-86.

McAllister-Williams RH, Sousa S, Kumar A, et al. The effects of vagus nerve stimulation on the course and outcomes of patients with bipolar disorder in a treatment-resistant depressive episode: a 5-year prospective registry. Int J Bipolar Disord. 2020;8(1):13.

Michael JE, Wegener K, Barnes DW. Vagus nerve stimulation for intractable seizures: one year follow-up. J Neurosci Nurs. 1993;25(6):362-366.

Miller S, Matharu M. Non-invasive neuromodulation in primary headaches. Curr Pain Headache Rep. 2017;21(3):14.

Morris GL, Gloss D, Buchhalter J, et al. Evidence-based guideline update: vagus nerve stimulation for the treatment of epilepsy: report of the Guideline Development Subcommittee of the American Academy of Neurology. Neurology. 2013;81(16):1453-1459.

Murphy JV. Left vagal nerve stimulation in children with medically refractory epilepsy. The Pediatric VNS Study Group. J Pediatr. 1999;134(5):563-566.

Mwamburi M, Liebler EJ, Tenaglia AT. Cost-effectiveness of gammaCore (non-invasive vagus nerve stimulation) for acute treatment of episodic cluster headache. Am J Manag Care. 2017a;23(16 Suppl):S300-S306.

Mwamburi M, Liebler EJ, Tenaglia AT. Review of non-invasive vagus nerve stimulation (gammaCore): efficacy, safety, potential impact on comorbidities, and economic burden for episodic and chronic cluster headache. Am J Manag Care. 201b;23(17 Suppl):S317-S325.

Mwamburi M, Tenaglia AT, Leibler EJ, et al. Cost-effectiveness of noninvasive vagus nerve stimulation for acute treatment of episodic migraine and role in treatment sequence strategies. Am J Manag Care. 2018;24(24 Suppl):S527-s533.

National Institute for Health and Care Excellence (NICE). gammaCore for cluster headache (MIB162). October 2018. Available at: https://www.nice.org.uk/advice/mib162. Accessed July 24, 2026.

National Institute for Health and Care Excellence (NICE). Implanted vagus nerve stimulation for treatment-resistant depression (IPG679). August 2020. Available at: https://www.nice.org.uk/guidance/ipg679/chapter/1-Recommendations. Accessed July 24, 2026.

National Institute for Health and Care Excellence (NICE). Medical technologies guidance [MTG46]: gammaCore for cluster headache. December 2019. Available at: https://www.nice.org.uk/guidance/MTG46. Accessed July 24, 2026.

National Institute for Health and Care Excellence (NICE). Transcutaneous stimulation of the cervical branch of the vagus nerve for cluster headache and migraine (IPG552). March 2016. Available at: https://www.nice.org.uk/guidance/ipg552/chapter/1-Recommendations. Accessed July 24, 2026.

Nearing BD, Libbus I, Carlson GM, et al. Chronic vagus nerve stimulation is associated with multi-year improvement in intrinsic heart rate recovery and left ventricular ejection fraction in ANTHEM-HF. Clin Auton Res. 2021;31(3):453-462.

Nesbitt AD, Marin JC, Tompkins E, et al. Initial use of a novel noninvasive vagus nerve stimulator for cluster headache treatment. Neurology. 2015;84(12):1249-1253.

Panebianco M, Rigby A, Weston J, et al. Vagus nerve stimulation for partial seizures. Cochrane Database Syst Rev. Apr 03 2015(4):CD002896.

Papasavas P, El Chaar M, Kothari SN, et al. American Society for Metabolic and Bariatric Surgery position statement on vagal blocking therapy for obesity. Surg Obes Relat Dis. 2016;12(3):460-461.

Parker AP, Polkey CE, Binnie CD, et al. Vagal nerve stimulation in epileptic encephalopathies. Pediatrics. 1999;103(4 Pt 1):778-782.

Patwardhan RV, Stong B, Bebin EM, et al. Efficacy of vagal nerve stimulation in children with medically refractory epilepsy. Neurosurgery. 2000;47(6):1353-1357; discussion 1357-1358.

Premchand RK, Sharma K, Mittal S, et al. A​utonomic regulation therapy via left or right cervical vagus nerve stimulation in patients with chronic heart failure: results of the ANTHEM-HF trial. J Card Fail. 2014;20(11):808-816.

Puledda F, Goadsby PJ. Current approaches to neuromodulation in primary headaches: Focus on vagal nerve and sphenopalatine ganglion stimulation. Curr Pain Headache Rep. 2016;20(7):47.

Purser MF, Mladsi DM, Beckman A, et al. Expected Budget Impact and Health Outcomes of Expanded Use of Vagus Nerve Stimulation Therapy for Drug-Resistant Epilepsy. Adv Ther. 2018;35(10):1686-1696.

ReShape LifesciencesTM. Summary of Transformative Technologies for the Treatment Continuum. Available at: https://www.reshapelifesciences.com/. Accessed July 24, 2026.

Reuter U, McClure C, Liebler E, et al. Non-invasive neuromodulation for migraine and cluster headache: a systematic review of clinical trials. J Neurol Neurosurg Psychiatry. 2019;90(7):796-804.

Rong P, Liu A, Zhang J, et al. Transcutaneous vagus nerve stimulation for refractory epilepsy: a randomized controlled trial. Clin Sci (Lond). Apr 01 2014.

Rush AJ, George MS, Sackeim HA, et al. Vagus nerve stimulation (VNS) for treatment-resistant depressions: a multicenter study. Biol Psychiatry. 2000;47(4):276-286.

Rush AJ, Marangell LB, Sackeim HA, et al. Vagus nerve stimulation for treatment-resistant depression: a randomized, controlled acute phase trial. Biol Psychiatry. 2005;58(5):347-354.

Ryvlin P, Gilliam FG, Nguyen DK, et al. The long-term effect of vagus nerve stimulation on quality of life in patients with pharmacoresistant focal epilepsy: the PuLsE (Open Prospective Randomized Long-term Effectiveness) trial. Epilepsia. 2014;55(6):893-900.

Sackeim HA, Rush AJ, George MS, et al. Vagus nerve stimulation (VNS) for treatment-resistant depression: efficacy, side effects, and predictors of outcome. Neuropsychopharmacology. 2001;25(5):713-728.

Sanchez-Gomez LM, Polo-deSantos M, Pinel-Gonzalez A, et al. Systematic review of the safety and effectiveness of peripheral neurostimulation of the sphenopalatine ganglion for the treatment of refractory chronic cluster headache. Neurologia. 2018 Jan 12 [Epub ahead of print].

Sant'Anna LB, Couceiro SLM, Ferreira EA, et al. Vagal Neuromodulation in Chronic Heart Failure With Reduced Ejection Fraction: A Systematic Review and Meta-Analysis. Front Cardiovasc Med. 2021;8:766676.

Sarr MG, Billington CJ, Brancatisano R, et al. The EMPOWER study: randomized, prospective, double-blind, multicenter trial of vagal blockade to induce weight loss in morbid obesity. Obes Surg. 2012;22(11):1771-1782.

Scherrmann J, Hoppe C, Kral T, et al. Vagus nerve stimulation: clinical experience in a large patient series. J Clin Neurophysiol. 2001;18(5):408-414.

Shi C, Flanagan SR, Samadani U. Vagus nerve stimulation to augment recovery from severe traumatic brain injury impeding consciousness: a prospective pilot clinical trial. Neurol Res. 2013;35(3):263-276. 

Shikora SA, Wolfe BM, Apovian CM, et al. Sustained weight loss with vagal nerve blockade but not with sham: 18-month results of the ReCharge Trial. J Obes. 2015;2015:365604.

Shiozawa P, Silva ME, Carvalho TC, et al. Transcutaneous vagus and trigeminal nerve stimulation for neuropsychiatric disorders: a systematic review. Arq Neuropsiquiatr. 2014;72(7):542-547.

Silberstein SD, Calhoun AH, Lipton RB et al. Chronic migraine headache prevention with noninvasive vagus nerve stimulation: The EVENT study. Neurology. 2016;87(5):529-538.

Silberstein SD, Calhoun AH, Treppendahl C, et al. The emerging role of gammaCore® in the management of cluster headache: Expert panel recommendations. Am J Manag Care. 2017;23(17 Suppl):S326-S333.

Silberstein SD, Mechtler LL, Kudrow DB, et al. Non-invasive vagus nerve stimulation for the ACute Treatment of Cluster Headache: findings from the randomized, double-blind, sham-controlled ACT1 Study. Headache. 2016;56(8):1317-1332.

Simon B, Blake J. Mechanism of action of non-invasive cervical vagus nerve stimulation for the treatment of primary headaches. Am J Manag Care. 2017;23(17 Suppl):S312-S316.

Stefan H, Kreiselmeyer G, Kerling F, et al. Transcutaneous vagus nerve stimulation (t-VNS) in pharmacoresistant epilepsies: a proof of concept trial. Epilepsia. 2012;53(7):e115-118.

Tassorelli C, Grazzi L, de Tommaso M et al. Noninvasive vagus nerve stimulation as acute therapy for migraine: The randomized PRESTO study. Neurology. 2018;91(4):e364-e373.

Terra VC, Furlanetti LL, Nunes AA, et al. Vagus nerve stimulation in pediatric patients: Is it really worthwhile? Epilepsy Behav. 2014;31:329-333.

Tfelt-Hansen P, Pascual J, Ramadan N, et al. Guidelines for controlled trials of drugs in migraine: third edition. A guide for investigators. Cephalalgia. 2012;32(1):6-38.

The Vagus Nerve Stimulation Study Group. A randomized controlled trial of chronic vagus nerve stimulation for treatment of medically intractable seizures. The Vagus Nerve Stimulation Study Group. Neurology. 1995;45(2):224-230.

Tisi G, Franzini A, Messina G, et al. Vagus nerve stimulation therapy in treatment-resistant depression: a series report. Psychiatry Clin Neurosci. 2014;68(8):606-611.

Trimboli M, Al-Kaisy A, Andreou AP et al. Non-invasive vagus nerve stimulation for the management of refractory primary chronic headaches: A real-world experience. Cephalalgia. 2018;38(7):1276-1285.

Tso AR, Marin J, Goadsby PJ. Noninvasive vagus nerve stimulation for treatment of indomethacin-sensitive headaches. JAMA Neurol. 2017;74(10):1266-1267.

U.S. Food and Drug Administration. 510(k) Premarket Notification: gammaCore-S (K171306). 2017. Available at: https://www.accessdata.fda.gov/cdrh_docs/pdf17/K171306.pdf. Accessed July 24, 2026.

U.S. Food and Drug Administration. Class 2 Device Recall Model 106 AspireSR Generators (P970003S173). 2017. Available at: https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfRES/res.cfm?id=157567. Accessed July 24, 2026.

U.S. Food and Drug Administration. Premarket Approval (PMA): Maestro Rechargeable System (P130019). 2020. Available at: https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfPMA/pma.cfm. Accessed July 24, 2026.

U.S. Food and Drug Administration. Premarket Approval (PMA): VNS Therapy System (P970003/S207). 2017. Available at: https://www.accessdata.fda.gov/cdrh_docs/pdf/p970003s207b.pdf. Accessed July 24, 2026.

U.S. Food and Drug Administration. Summary of Safety and Effectiveness Data (SSED): Maestro Rechargeable System. 2015. Available at: http://www.accessdata.fda.gov/cdrh_docs/pdf13/P130019B.pdf. Accessed July 24, 2026.

U.S. Food and Drug Administration. Summary of Safety and Effectiveness Data: VNS Therapy TM System. 2005. Available at: https://www.accessdata.fda.gov/cdrh_docs/pdf/p970003s050b.pdf. Accessed July 24, 2026.

U.S. Food and Drug Administration. Weight-Loss and Weight-Management Devices. April 27, 2020. Available at: https://www.fda.gov/medical-devices/products-and-medical-procedures/weight-loss-and-weight-management-devices. Accessed July 24, 2026.​​

Vonck K, Boon P, D'Have M, et al. Long-term results of vagus nerve stimulation in refractory epilepsy. Seizure. 1999;8(6):328-334.

Vonck K, Thadani V, Gilbert K, et al. Vagus nerve stimulation for refractory epilepsy: a transatlantic experience. J Clin Neurophysiol. 2004;21(4):283-289.

Wei J, Zhang C, Wang JX, et al. The effect of VNS on the rehabilitation of stroke: A meta-analysis of randomized controlled studies. J Clin Neurosci. 2020;81:421-425.

Wei, T., Ge, X., Lu, L., Li, J., Xu, P., & Wu, Q. (2023). Efficacy and safety of vagus nerve stimulation on upper extremity motor function in patients with stroke: A meta-analysis of randomized controlled trials1. NeuroRehabilitation, 53(3), 253–267. https://doi.org/10.3233/nre-230106​.

Wu D, Ma J, Zhang L, et al. Effect and Safety of Transcutaneous Auricular Vagus Nerve Stimulation on Recovery of Upper Limb Motor Function in Subacute Ischemic Stroke Patients: A Randomized Pilot Study. Neural Plast. 2020;2020:8841752.

Wu K, Wang Z, Zhang Y, et al. Transcutaneous vagus nerve stimulation for the treatment of drug-resistant epilepsy: a meta-analysis and systematic review. ANZ J Surg. 2020;90(4):467-471.

You SJ, Kang HC, Kim HD, et al. Vagus nerve stimulation in intractable childhood epilepsy: a Korean multicenter experience. J Korean Med Sci. 2007;22(3):442-445.

Yu C, Ramgopal S, Libenson M, et al. Outcomes of vagal nerve stimulation in a pediatric population: A single center experience. Seizure. 2014;23(2):105-111.

Yuan H, Silberstein SD. Vagus nerve stimulation and headache. Headache. 2017;57 Suppl 1:29-33.

Zannad F, De Ferrari GM, Tuinenburg AE, et al. Chronic vagal stimulation for the treatment of low ejection fraction heart failure: results of the NEural Cardiac TherApy foR Heart Failure (NECTAR-HF) randomized controlled trial. Eur Heart J. 2015;36(7):425-433.​​​

Coding

CPT Procedure Code Number(s)
MEDICALLY NECESSARY

0908T, 0909T, 0910T, 0911T, 0912T, 61885, 61888, 64553, 64568, 64569, 64570, 95970, 95976, 95977

EXPERIMENTAL/INVESTIGATIONAL
​
THE FOLLOWING CODE IS USED TO REPRESENT VAGUS NERVE BLOCKING THERAPY FOR THE TREATMENT OF MORBID OBESITY

64999

ICD - 10 Procedure Code Number(s)
N/A

ICD - 10 Diagnosis Code Number(s)
MEDICALLY NECESSARY

G40.011 Localization-related (focal) (partial) idiopathic epilepsy and epileptic syndromes with seizures of localized onset, intractable, with status epilepticus

G40.019 Localization-related (focal) (partial) idiopathic epilepsy and epileptic syndromes with seizures of localized onset, intractable, without status epilepticus

G40.111 Localization-related (focal) (partial) symptomatic epilepsy and epileptic syndromes with simple partial seizures, intractable, with status epilepticus

G40.119 Localization-related (focal) (partial) symptomatic epilepsy and epileptic syndromes with simple partial seizures, intractable, without status epilepticus

G40.211 Localization-related (focal) (partial) symptomatic epilepsy and epileptic syndromes with complex partial seizures, intractable, with status epilepticus

G40.219 Localization-related (focal) (partial) symptomatic epilepsy and epileptic syndromes with complex partial seizures, intractable, without status epilepticus

G40.311 Generalized idiopathic epilepsy and epileptic syndromes, intractable, with status epilepticus

G40.319 Generalized idiopathic epilepsy and epileptic syndromes, intractable, without status epilepticus

G40.411 Other generalized epilepsy and epileptic syndromes, intractable, with status epilepticus

G40.419 Other generalized epilepsy and epileptic syndromes, intractable, without status epilepticus

G40.803 Other epilepsy, intractable, with status epilepticus

G40.804 Other epilepsy, intractable, without status epilepticus

G40.813 Lennox-Gastaut syndrome, intractable, with status epilepticus

G40.814 Lennox-Gastaut syndrome, intractable, without status epilepticus

G40.823 Epileptic spasms, intractable, with status epilepticus

G40.824 Epileptic spasms, intractable, without status epilepticus

G40.841 KCNQ2-related epilepsy, not intractable, with status epilepticus

G40.842 KCNQ2-related epilepsy, not intractable, without status epilepticus

G40.843 KCNQ2-related epilepsy, intractable, with status epilepticus

G40.844 KCNQ2-related epilepsy, intractable, without status epilepticus

G40.89 Other seizures

G40.A11 Absence epileptic syndrome, intractable, with status epilepticus

G40.A19 Absence epileptic syndrome, intractable, without status epilepticus

G40.B11 Juvenile myoclonic epilepsy, intractable, with status epilepticus

G40.B19 Juvenile myoclonic epilepsy, intractable, without status epilepticus

G40.C01 Lafora progressive myoclonus epilepsy, not intractable, with status epilepticus

G40.C09 Lafora progressive myoclonus epilepsy, not intractable, without status epilepticus

G40.C11 Lafora progressive myoclonus epilepsy, intractable, with status epilepticus

G40.C19 Lafora progressive myoclonus epilepsy, intractable, without status epilepticus​

EXPERIMENTAL/INVESTIGATIONAL
​
IMPLANTABLE VAGUS NERVE STIMULATION

See Attachment A.

NON-IMPLANTABLE VAGUS NERVE STIMULATION

See Attachment B.

HCPCS Level II Code Number(s)
MEDICALLY NECESSARY

C1767 Generator, neurostimulator (implantable), non-rechargeable

C1778 Lead, neurostimulator (implantable)

C1816 Receiver and/or transmitter, neurostimulator (implantable)

C1820 Generator, neurostimulator (implantable), with rechargeable battery and charging system

C1822 Generator, neurostimulator (implantable), high frequency, with rechargeable battery and charging system

C1883 Adaptor/extension, pacing lead or neurostimulator lead (implantable)

C1897 Lead, neurostimulator test kit (implantable)

L8678 Electrical stimulator supplies (external) for use with implantable neurostimulator, per month​

L8679 Implantable neurostimulator, pulse generator, any type

L8680 Implantable neurostimulator electrode, each

L8681 Patient programmer (external) for use with implantable programmable neurostimulator pulse generator, replacement only

L8682 Implantable neurostimulator radiofrequency receiver

L8683 Radiofrequency transmitter (external) for use with implantable neurostimulator radiofrequency receiver

L8685 Implantable neurostimulator pulse generator, single array, rechargeable, includes extension

L8686 Implantable neurostimulator pulse generator, single array, non-rechargeable, includes extension

L8687 Implantable neurostimulator pulse generator, dual array, rechargeable, includes extension

L8688 Implantable neurostimulator pulse generator, dual array, non-rechargeable, includes extension

L8689 External recharging system for battery (internal) for use with implantable neurostimulator, replacement only

L8695 External recharging system for battery (external) for use with implantable neurostimulator, replacement only

EXPERIMENTAL/INVESTIGATIONAL

​C1827​​ Generator, neurostimulator (implantable), nonrechargeable, with implantable stimulation lead and external paired stimulation controller

E0735 Non-invasive vagus nerve stimulator

Revenue Code Number(s)
N/A



Coding and Billing Requirements


Policy History

Revisions From 11.15.16y:
10/19/2026
This version of the policy is effective as of 10/19/2026. The revised policy number is 11.15.16y. ​​

The MicroTransponder ViviStim Paired Vagus Nerve Stimulation (VNS) system for implantable VNS for use in the treatment of individuals who have upper-limb impairment due to stroke​ is currently experimental/investigational (E/I) and not a new coverage determination but newly added to this document.​​

The FDA verbiage for Implantable Vagus Nerve Stimulation upper-limb impairment due to stroke has been added to this policy:
  •  (i.e., MicroTransponder ViviStim Paired Vagus Nerve Stimulation (VNS) system for implantable vagus nerve stimulation for use in the treatment of individuals who have upper-limb impairment due to stroke, the Company has determined that the safety and/or effectiveness of this service cannot be established by review of the available published peer-reviewed literature. Therefore, implantable vagus nerve stimulation for use in the treatment of individuals who have upper-limb impairment due to stroke is considered experimental/investigational by the Company and not covered. 

Revisions From 11.15.16x:
10/01/2026
​This version of the policy will become effective 10/01/2026.

T
he following CPT codes have been added to the policy (Experimental/ Investigational):

  • 1057T Insertion or replacement of subcutaneous neurostimulator pulse generators, with tunneling of 4 electrode arrays, bilateral supraorbital and occipital nerves, including all interrogation, programming, and imaging guidance, when performed
  • 1058T Revision of implanted subcutaneous unilateral supraorbital and occipital neurostimulator system, including all interrogation, programming, and imaging guidance, when performed
  • 1059T Removal of implanted subcutaneous unilateral supraorbital and occipital neurostimulator system
  • 1060T Electronic analysis of implanted subcutaneous supraorbital-occipital neurostimulator pulse generator (eg, frequency, amplitude, pulse width, leads, electrode configuration); with complex programming by physician or other qualified health care professional
  • 1061T Electronic analysis of implanted subcutaneous supraorbital-occipital neurostimulator pulse generator (eg, frequency, amplitude, pulse width, leads, electrode configuration); with simple programming by physician or other qualified health care professional

Revisions From 11.15.16w:
​12/10/2025
​This policy has been reviewed and reissued to communicate the Company’s continuing position on vagus nerve stimulation (VNS).​​​
01/06/2025

​This version of the policy will become effective 01/06/2025.

The following CPT codes have been added to this policy (Medically Necessary):

​​0908T, 0909T, 0910T, 0911T, 0912T​

T
he following ICD-10 codes have been added to the policy (Medically Necessary):

G40.813 Lennox-Gastaut syndrome, intractable, with status epilepticus
G40.814 Lennox-Gastaut syndrome, intractable, without status epilepticus​

The following CPT Code has been deleted from the policy:
0783T​

Revisions From 11.15.16v:
10/01/2024
​This policy has been identified for the ICD-10 code update, effective 10/01/2024.

The following ICD- 10 codes have been added to the policy:
G40.841 KCNQ2-related epilepsy, not intractable, with status epilepticus
G40.842 KCNQ2-related epilepsy, not intractable, without status epilepticus
G40.843 KCNQ2-related epilepsy, intractable, with status epilepticus
G40.844 KCNQ2-related epilepsy, intractable, without status epilepticus

The following ICD-10 Code has been deleted from Attachment A:

E66.8 Other Obesity 

and replaced with the following ICD-10 Codes in Attachment A:

E66.811 Obesity, class 1
E66.812 Obesity, class 2
E66.813 Obesity, class 3
E66.89 Other obesity not elsewhere classified
E88.82 Obesity due to disruption of MC4R pathway


R
evisions From 11.15.16u:
​01/02/2024
​This policy has been identified for the HCPCS code update, effective 01/02/2024.

The following HCPCS Code has been termed:

K1020 Non-invasive vagus nerve stimulator

and replaced with the following HCPCS Code:

​E0735 Non-invasive vagus nerve stimulator


Revisions From 11.15.16t:
​10/01/2023
​This policy has been identified for the ICD-10 Diagnosis code update, effective 10/01/2023.

The following ICD-10 Diagnosis Codes have been added to this policy:
  • G40.C01 Lafora progressive myoclonus epilepsy, not intractable, with status epilepticus
  • G40.C09 Lafora progressive myoclonus epilepsy, not intractable, without status epilepticus
  • G40.C11 Lafora progressive myoclonus epilepsy, intractable, with status epilepticus
  • G40.C19 Lafora progressive myoclonus epilepsy, intractable, without status epilepticus
  • ​​G43.E01 Chronic migraine with aura, not intractable, with status migrainosus​
  • G43.E09 Chronic migraine with aura, not intractable, without status migrainosus
  • G43.E11 Chronic migraine with aura, intractable, with status migrainosus
  • G43.E19 Chronic migraine with aura, intractable, without status migrainosus​

Revisions From 11.15.16s:
08/23/2023
This policy has been reissued in accordance with the Company's annual review process.
​04/01/2023
​This policy has been identified for the HCPCS code update, effective 04/01/2023.

The following HCPCS Code has been added to this policy:

​L8678 Electrical stimulator supplies (external) for use with implantable neurostimulator, per month​

Revisions From 11.15.16r:
01/01/2023
This version of the policy will become effective 01/01/2023.

The following indication for Implantable Vagus Nerve Stimulation is considered Experimental/Investigational and has been added to this policy:

  • Obsessive-compulsive disorder (OCD)
The following indications for Non-Implantable Vagus Nerve Stimulation are considered Experimental/Investigational and have been added to this policy:

  • Fibromyalgia
  • Impaired glucose tolerance
  • ​Psychiatric disorders, including, but not limited to depression and schizophrenia
  • Upper-limb impairment due to stroke
Attachments A and B were created to list ICD-10 Diagnosis Codes that are considered Experimental/Investigational for Implantable Vagus Nerve Stimulation (Attachment A) and Non-Implantable Vagus Nerve Stimulation (Attachment B).
____________________________________________________________________

On 12/12/2022, the following 1/1/2023 CPT code updates were made to this policy while in Notification:

  • The following Experimental/Investigational CPT Codes have been termed (no longer valid codes) and removed from this policy: 0312T, 0313T, 0314T, 0315T, 0316T, ​0317T
  • ​CPT Codes 0312T-0317T are replaced by the following NOC code: 64999
  • The following CPT Code has been added to this policy as Experimental/Investigational: 0783T

Revisions From 11.15.16q:
01/01/2022
This policy has been identified for the CPT code update, effective 01/01/2022.

The following CPT narrative has been revised in this policy: 64568

Revisions From 11.15.16p:
06/16/2021
The policy has been reviewed and reissued to communicate the Company's continued position on Vagus Nerve Stimulation (VNS).
​04/01/2021
​This policy has been identified for the HCPCS code update, effective 04/01/2021.

The following NOC code has been removed from this policy and is replaced by the following HCPCS code:

REMOVED: E1399 Durable medical equipment, miscellaneous
REPLACED WITH: K1020 Non-invasive vagus nerve stimulator​​

Revisions From 11.15.16o:
10/26/2020
The following indication for Implantable Vagus Nerve Stimulation is considered Experimental/Investigational and was added to this policy:
  • Upper-limb impairment due to stroke
Coverage of Vagus Nerve Stimulation for the treatment of refractory depression was changed from Not Medically Necessary to Experimental/Investigational. Policy language was revised to reflect this change.

The Description Section was updated with new literature.

The following CPT Procedure Code was added to this policy as Medically Necessary: 64553

The following unlisted procedure code used to represent implantable vagus nerve stimulation for chronic heart failure was removed from this policy: 64999

The following HCPCS codes were added to this policy as Medically Necessary: C1767, C1778, C1816, C1820, C1822, C1883, C1897

Revisions From 11.15.16n:
01/21/2019This version of the policy is effective as of 01/21/2019.

Major update to this policy bulletin includes the following:

Non-implantable vagus nerve stimulation, (e.g., gammaCore™ [non-invasive vagus nerve stimulator (nVNS)]), is considered experimental/investigational and, therefore, not covered because the safety and/or effectiveness of this service cannot be established by review of the available published peer-reviewed literature in the treatment for conditions, including, but not limited to the following:
  • Epilepsy
  • Migraine headaches
  • Cluster headaches

  • Revisions From 11.15.16m:
    01/01/2018This policy has been identified for the CPT code update, effective 01/01/2018.

    The following CPT code has been removed from this policy (out of scope): 64550

    Effective 10/05/2017 this policy has been updated to the new policy template format.
    10/19/2026
    10/19/2026
    11.15.16
    Medical Policy Bulletin
    Commercial
    {"8824": {"Id":8824,"MPAttachmentLetter":"B","Title":"Experimental/Investigational ICD-10 Diagnosis Codes for Non-Implantable Vagus Nerve Stimulation","MPPolicyAttachmentInternalSourceId":10865,"PolicyAttachmentPageName":"da2d189f-6c53-44c6-bc3b-aed5e2e3004a"},"8825": {"Id":8825,"MPAttachmentLetter":"A","Title":"Experimental/Investigational ICD-10 Diagnosis Codes for Implantable Vagus Nerve Stimulation","MPPolicyAttachmentInternalSourceId":10866,"PolicyAttachmentPageName":"ebe34f56-1b4a-4e3f-955d-88dc68e6b857"},}
    No